Conformable thin-film cuff electrodes as tools for peripheral nerve recording: a comparative study.
Amparo Güemes, Margaux O A Forner, Ariadna Guindo-Arroyo, Ruben Ruiz-Mateos Serrano, George G Malliaras, Alejandro Carnicer-Lombarte
Department of Engineering, Institute for Biomedical Innovation, University of Cambridge, Cambridge, United Kingdom. · Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR, China.
Key points
From the paper's conclusion- Our findings support that conformable thin-film cuffs are competitive research tools for acute peripheral nerve recording.
Abstract
Peripheral nerve recordings are a powerful research technique commonly performed using commercially available elastomeric cuff electrodes. However, emerging conformable thin-film technologies which offer advantages in device flexibility, feature miniaturisation, and electrode layout may represent an important alternative tool. In this study, we compare these two device classes as acute recording tools by implanting them side-by-side on rat sciatic nerves under anaesthesia and recording activity evoked by nociceptive muscle stimulation or proprioceptive ankle extension. We find that conventional elastomeric cuffs and conformable thin-film cuffs exhibit no statistically significant signal-to-noise ratio differences under this experimental regime, either under monopolar or referenced recording paradigms. When performing signal velocity analysis, conformable thin-film cuffs show a tendency to toward more frequently classifying recorded sensory activity as afferent, compared to conventional cuffs. Our findings support that conformable thin-film cuffs are competitive research tools for acute peripheral nerve recording.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An open-source thin film extraneural cuff electrode for peripheral nerve stimulation.IEEE transactions on bio-medical engineering · 2026
- Influences of design aspects on recording functionality of cuff-type peripheral nerve interfaces.Journal of neural engineering · 2026
- Extreme manufacturing of minimally invasive intracortical neural electrodesInternational Journal of Extreme Manufacturing · 2025
- Conformal Thermoreversible Gelatin-Based Gel for High-Fidelity Electrophysiological Recording and Acute Peripheral Nerve Interfacing.Advanced materials (Deerfield Beach, Fla.) · 2026
- Flexible Microneedle Array Electrode with Improved Comfort, Low Impedance, and High Performance for Electrophysiological Recording.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Multi-scale computational modeling of magnetoelectric nanoparticle-dispersed conductive nanofibers for peripheral nerve modulation.Frontiers in bioengineering and biotechnology · 2026