A single model for glioblastoma segmentation with and without T2-FLAIR: independent validation of a targeted dropout strategy.
Marco Öchsner, Lena Kaiser, Robert Stahl, Nathalie L Albert, Thomas Liebig, Robert Forbrig, Jonas Reis
Institute of Neuroradiology, LMU University Hospital, LMU, Munich, Germany. · Department of Nuclear Medicine, LMU University Hospital, LMU, Munich, Germany.
Key points
From the paper's conclusion- In the independent withheld UPenn-GBM cohort, targeted T2-FLAIR dropout preserved complete-protocol performance and remained robust when T2-FLAIR was unavailable. Because a dedicated three-sequence model matched this performance without T2-FLAIR, the value of targeted dropout lies not in superior missing-sequence accuracy but in providing a single model that operates across both complete and T2-FLAIR-unavailable inference.
Abstract
OBJECTIVES: To evaluate targeted T2 fluid-attenuated inversion recovery (T2-FLAIR) dropout for robust automated glioblastoma segmentation and volumetry when T2-FLAIR is unavailable, while preserving performance when the full MRI protocol is available. MATERIALS AND METHODS: In this retrospective multi-dataset study, 3D nnU-Net models were developed on BraTS 2021 after excluding UPenn-GBM cases (remaining n = 848) and evaluated in the independent withheld UPenn-GBM cohort (n = 403). Models were trained with or without targeted T2-FLAIR dropout by zeroing the T2-FLAIR channel during training. Testing used prespecified T2-FLAIR-present and T2-FLAIR-unavailable scenarios, where the unavailable scenario was simulated by zeroing the T2-FLAIR channel at inference. The primary endpoint was per-patient overall region-wise Dice similarity coefficient (DSC). Secondary endpoints were region-specific DSC, 95th percentile Hausdorff distance and Bland-Altman whole-tumor volume bias. RESULTS: In the UPenn-GBM validation cohort, performance was preserved with the full MRI protocol: overall median DSC was 94.8% [interquartile range (IQR) 90.0-97.1%] with 35% dropout and 95.0% (IQR 90.3-97.1%) without dropout. In the T2-FLAIR-unavailable scenario, targeted dropout improved overall median DSC from 81.0% (IQR 75.1-86.4%) to 93.4% (IQR 89.1-96.2%). Whole-tumor DSC improved from 60.4 to 92.6%, whole-tumor 95th percentile Hausdorff distance from 17.24 mm to 2.45 mm, and whole-tumor volume bias from -45.6 mL to 0.83 mL. A dedicated three-sequence nnU-Net achieved similar performance without T2-FLAIR (overall DSC 93.8%, WT DSC 93.5%), suggesting that much of this recovery reflects adaptation to the reduced-input setting rather than dropout training specifically. CONCLUSION: In the independent withheld UPenn-GBM cohort, targeted T2-FLAIR dropout preserved complete-protocol performance and remained robust when T2-FLAIR was unavailable. Because a dedicated three-sequence model matched this performance without T2-FLAIR, the value of targeted dropout lies not in superior missing-sequence accuracy but in providing a single model that operates across both complete and T2-FLAIR-unavailable inference.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Beyond proof-of-concept: Validating robust automated diffuse lower-grade glioma segmentation for clinical applications in longitudinal follow-upNeuro-Oncology Advances · 2025
- IMG-06 Tumor biology as a predictor of glioma segmentation failure across 0.3T to 3T MRINeuro-Oncology · 2026
- Contrast-Enhancing Tumor Margin Detection in Gliomas using Non-Contrast MRI: From Human-Only to Human-AI Assisted Assessment.Neuroradiology · 2026
- IMGP-11 Real-World-Ready Deep Learning for Pediatric Neuro-Oncology: Robust Segmentation and Prognosis with Missing MRI SequencesNeuro-Oncology · 2026
- Automated RANO 2.0-Aligned Response Assessment for Glioblastoma Clinical Trials: External Evaluation Against Expert Annotations.Cancers · 2026
- RSAA-UNet: A Residual Squeeze-and-Excitation Attention U-Net with Atrous Context and Focal-Tversky Supervision for Lower-Grade Glioma Segmentation on FLAIR MRI under a Patient-Wise Evaluation ProtocolIJARCCE · 2026