IMG-06 Tumor biology as a predictor of glioma segmentation failure across 0.3T to 3T MRI
Ilyas Oultache, Udunna Anazodo, Mohannad Barakat, Ugumba Kwikima, Omidiji Abeni, Amal Nour, Chinasa Kalaiwo, Yodit Yaynishet,
Key points
From the paper's conclusion- We externally validated a missing-modality model on a cohort extending to 0.3T, below the training minimum of 0.5T, to determine whether segmentation failures are driven by scanner hardware or tumor biology.
Abstract
Background AI glioma segmentation tools validated on curated 3T datasets cannot serve most neuro-oncology practices globally, where low-field scanners, incomplete protocols, and limited contouring resources predominate. We externally validated a missing-modality model on a cohort extending to 0.3T, below the training minimum of 0.5T, to determine whether segmentation failures are driven by scanner hardware or tumor biology. Methods The model was trained on 1,697 cases from BraTS 2023, BraTS-Africa, and the Erasmus Glioma Database (0.5T-3T), with augmentation for field-strength variation, anisotropic acquisition, and partial contrast attenuation. External validation used 362 preoperative glioma cases from UT Southwestern Medical Center spanning 0.3T to 3T, including 236 grade 4 and 124 grade 2-3 tumors, evaluated across all 15 nonempty T1n/T1c/T2w/T2-FLAIR combinations with test-time augmentation. Failure-mode analyses tested field strength, grade, IDH status, and 1p/19q codeletion with Holm-Bonferroni correction. Results Grade 4 tumors achieved a mean Dice 0.806 (95% CI 0.784 to 0.828; median 0.869), whole-tumor Dice 0.883, tumor-core Dice 0.757, and enhancing-tumor Dice 0.778, consistent with published high-grade benchmarks while extending coverage to 0.3T. The T1c + T2-FLAIR protocol, feasible in resource-limited settings, preserved 97% of full-protocol performance (mean Dice 0.780). Scanner field strength was not a significant predictor of failure (p = 0.324). Grade 2-3, IDH-mutant, and 1p/19q-codeleted tumors had lower performance (mean Dice scores of 0.448, 0.476, and 0.420; all p < 0.001), consistent with nonenhancing, infiltrative phenotypes. External validation consumed 1.24 kWh (32.3 g CO2eq). Conclusions Segmentation failures aligned with lower-grade, IDH-mutant tumor biology rather than scanner field strength, challenging the assumption that hardware heterogeneity is the principal barrier to AI deployment in neuro-oncology. These findings support the use of abbreviated protocols for surgical planning, radiotherapy contouring, and treatment response monitoring, and advocate for health-equity-oriented AI validation strategies encompassing low-field MRI environments serving populations in sub-Saharan Africa and other resource-limited settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Does Tumor-Mask Guidance Improve Glioma Grade Classification from T2-Weighted MRI Alone? An Out-of-Fold Evaluation with nnU-Net and Ground-Truth Localization.Journal of imaging · 2026
- Latent knowledge-driven unified representation learning for brain tumor segmentation with missing modalities.Neural networks : the official journal of the International Neural Network Society · 2026
- Artificial Intelligence in MRI-Based Glioma Imaging: From Radiomics-Based Machine Learning to Deep Learning ApproachesBioMedInformatics · 2026
- NeuroWeave-3D: Uncertainty-Aware Evidence Completion for Brain Tumor Segmentation with Missing MRI ModalitiesbioRxiv · 2026
- A single model for glioblastoma segmentation with and without T2-FLAIR: independent validation of a targeted dropout strategy.Frontiers in neurology · 2026
- Integrating deep learning and radiomics for preoperative glioma grading using multi-center MRI dataScientific Reports · 2025