Assessing the performance of artificial intelligence in detecting electrographic status epilepticus when human experts often disagree.
Khalid Alsherbini, Michelle Armenta Salas, Suganya Karunakaran, Archit Gupta, Baharan Kamousi, Raymond Woo, Veeresh Kumar N Shivamurthy, David King-Stephens,
Department of Neurology, Banner Health, University of Arizona, Phoenix, AZ, United States. · Ceribell Inc., Sunnyvale, CA, United States.
Key points
From the paper's conclusion- Of 604 POC EEGs, the group majority identified 8 cases (1.3%) meeting ACNS criteria for ESE and 14 (2.3%) with seizures, the rest were classified as normal/slowing (80.1%), highly epileptiform patterns (6.6%), or other findings (4.3%). Twentynine cases lacked consensus interpretation. Interrater agreement among reviewers was 0.67-0.68. Compared to the group majority, the AI algorithm showed higher sensitivity (median 100%) with lower specificity (93.5%) than individual reviewers (median sensitivity 60%, specificity 98.7%). Using all possible 3-reviewer combinations to define majority agreement, the number of EEGs identified as ESE varied widely (4-18 cases, median = 10). The AI algorithm consistently achieved significantly higher sensitivity than external human reviewers (71.4% vs. 50%, p < 0.001). However, the AI's specificity, while still high (median = 93.9%), was slightly lower than that of human reviewers (median = 98.4%, p < 0.001), though the AI's specificity had consistently narrower spread.
Abstract
OBJECTIVE: Generating reference standards to train and evaluate the accuracy of artificial intelligence (AI) algorithms poses a significant challenge. Particularly when interpreting complex signals like electroencephalography (EEG), where interrater variability is considerable. We aimed to characterize the impact of interrater variability when evaluating the performance of an AI algorithm for detecting electrographic status epilepticus in point-of-care (POC) limited-montage EEG. METHODS: We analyzed 604 EEGs collected using a POC EEG system (Ceribell Inc.). Each EEG was independently reviewed by 5-7 blinded experts, who annotated seizures and completed standardized assessments. The EEGs were later analyzed by the Clarity AI algorithm (version 7), trained on separate EEG dataset. Interrater agreement was assessed using Gwet's AC1. Sensitivity and specificity for detecting electrographic status epilepticus (ESE) were estimated for the reviewers and the AI algorithm. Multiple evaluation schemes were employed, including simple majority consensus of the full group (group majority), simple majority using leave-one-out analysis, and 2-of-3 majority with bootstrap sampling. RESULTS: Of 604 POC EEGs, the group majority identified 8 cases (1.3%) meeting ACNS criteria for ESE and 14 (2.3%) with seizures, the rest were classified as normal/slowing (80.1%), highly epileptiform patterns (6.6%), or other findings (4.3%). Twentynine cases lacked consensus interpretation. Interrater agreement among reviewers was 0.67-0.68. Compared to the group majority, the AI algorithm showed higher sensitivity (median 100%) with lower specificity (93.5%) than individual reviewers (median sensitivity 60%, specificity 98.7%). Using all possible 3-reviewer combinations to define majority agreement, the number of EEGs identified as ESE varied widely (4-18 cases, median = 10). The AI algorithm consistently achieved significantly higher sensitivity than external human reviewers (71.4% vs. 50%, p < 0.001). However, the AI's specificity, while still high (median = 93.9%), was slightly lower than that of human reviewers (median = 98.4%, p < 0.001), though the AI's specificity had consistently narrower spread. DISCUSSION: This study highlights the challenges of defining the correct answer for EEG interpretation, especially for ESE, and its consequences for evaluating seizure detection AI tools. Future work should explore how AI assistance impacts human interpretation, particularly in reducing interrater variability across a broader range of EEG patterns.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial intelligence-assisted categorization of interictal abnormalities in adult long-term electroencephalographic monitoring: Comparable diagnostic accuracy with marked efficiency gain.Epilepsia · 2026
- Artificial intelligence for automated detection of interictal epileptiform discharges: methodological progress, clinical evaluation, and neurodevelopmental context.Frontiers in cell and developmental biology · 2026
- Honest and Reliable Evaluation and Expert Equivalence Testing of Automated Neonatal Seizure Detection.Medical engineering & physics · 2026
- Automated Classification of Clinical EEG Reports as Normal or Pathological Using Natural Language Processing: A Multi-Centre StudymedRxiv · 2026
- Inter-rater reliability in drug-induced sleep endoscopy: experience-driven interpretation, decision-making, and the emerging role of artificial intelligence.Sleep & breathing = Schlaf & Atmung · 2026
- Automated Interictal Epileptiform Discharge Detector Scores in Serial EEG: Record-Level Concordance Did Not Extend to Within-Participant Change.Clinical EEG and neuroscience · 2026