Subject-independent gait activity recognition using DSAF: dual-stream IMU-EMG attention fusion with asymmetric temporal encoding and physiological complementarity weighting.
Zhangyue Xu, Yan Zhu, Shurui Li
School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai, China. · School of Mathematics, East China University of Science and Technology, Shanghai, China.
Key points
From the paper's conclusion- DSAF achieves 96.41% accuracy, 96.08% macro-precision, 95.62% macro-recall, and 95.81% macro-F1, consistently outperforming recent sequence-learning baselines across all 18 held-out subjects. Ablation studies further confirm that both the modality-specific encoding and the adaptive fusion mechanism contribute positively to the performance.
Abstract
INTRODUCTION: Accurate gait recognition using wearable sensors is of significant clinical value for adaptive prosthetic control, lower-limb exoskeleton assistance, and objective rehabilitation assessment. However, subject-independent recognition remains a major challenge, as unseen individuals can exhibit highly variable limb kinematics and muscle activation patterns, and existing approaches often rely on a single sensor modality or naive fusion strategies that fail to leverage the complementary information between inertial and electromyographic signals. METHODS: To address these gaps, this study proposes DSAF, a dual-stream attention fusion network that separately encodes kinematic (IMU) and neuromuscular (EMG) information, and adaptively integrates them through a physiological complementarity weighting mechanism designed for window-level modality adaptation. The framework is evaluated on the public HuGaDB dataset for eight common locomotion activities (e.g., walking, running, stair negotiation, and sit-to-stand transitions), using a leave-one-subject-out protocol to rigorously assess generalization to new users. RESULTS: DSAF achieves 96.41% accuracy, 96.08% macro-precision, 95.62% macro-recall, and 95.81% macro-F1, consistently outperforming recent sequence-learning baselines across all 18 held-out subjects. Ablation studies further confirm that both the modality-specific encoding and the adaptive fusion mechanism contribute positively to the performance. DISCUSSION: These findings indicate that adaptive IMU-EMG fusion can effectively strengthen wearable gait recognition, providing a promising solution for real-world rehabilitation monitoring and assistive human-machine interfaces.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Gait-Conditioned Human-in-the-Loop Optimization Framework Based on Gait-Assistance-Response Relationship Model for Exoskeleton Assistance.Bioengineering (Basel, Switzerland) · 2026
- Explainable Gait Multi-Anchor Space-Aware Temporal Convolutional Networks for Gait Recognition in Neurological, Orthopedic, and Healthy CohortsMathematics · 2026
- IMU- and LSTM-CNN-based multi-gait recognition for a lower limb exoskeletonFrontiers in Mechanical Engineering · 2026
- A Gait-Phase-Aware Adaptive Extended Kalman Filter for Drift-Free IMU Sensor Fusion and Gait Segmentation.Medical engineering & physics · 2026
- A multimodal EMG-IMU dataset and multi-dataset benchmark for deep learning-based human activity recognition.Scientific reports · 2026
- TSDGNet: Multiscale Temporal and Dual-Graph Learning for Pathological Gait Classification Using Wearable Inertial Sensors.Biosensors · 2026