Medical engineering & physics

A Gait-Phase-Aware Adaptive Extended Kalman Filter for Drift-Free IMU Sensor Fusion and Gait Segmentation.

Monisha Gowri Srinivasan, Tharani Kumaran, Ravi Kant Avvari, Thirugnanam Arunachalam

Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, Rourkela, OD, 769008, India. · Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, NIT Rourkela, Rourkela, 769008, India.

Computational

Key points

From the paper's conclusion
  • This study introduces a Gait-Phase-Aware Adaptive Extended Kalman Filter (GPA-EKF) featuring phase-conditioned process noise covariance (QH=10-2 for heel-strike, QL=10-5 for mid-stance, QM=10-4 for propulsion/swing) and compares ten supervised learning algorithms using 28 windowed time-domain features from triaxial accelerometer and gyroscope data.

Abstract

Wearable inertial measurement unit (IMU) based gait monitoring is a portable alternative to optical systems, yet no study has benchmarked a broad classifier set for binary and four-phase classification from shank-mounted sensors with concurrent optical validation. This study introduces a Gait-Phase-Aware Adaptive Extended Kalman Filter (GPA-EKF) featuring phase-conditioned process noise covariance (QH=10-2 for heel-strike, QL=10-5 for mid-stance, QM=10-4 for propulsion/swing) and compares ten supervised learning algorithms using 28 windowed time-domain features from triaxial accelerometer and gyroscope data. Twenty volunteers walked simultaneously with the ESP32-MPU6050 device and the Qualisys track manager (QTM) eight-camera optical system. The GPA-EKF improved orientation estimation by 47.5% (RMSE: 0.96° vs. 1.83°). Under strict subject-wise validation, ensemble methods performed best: a soft-voting ensemble (VOT) achieved 92.30% binary accuracy, and XGBoost/VOT achieved 83.80% four-phase accuracy (Light Gradient Boosting Machine, LightGBM: 91.50%/83.40%), with AUC up to 0.943 and sub-100 ms inference latency. All nine spatiotemporal indices showed excellent agreement with QTM references (ICC > 0.972; error < 2.1%; paired t-test p > 0.05). Speed, interpretability, and validated accuracy support real-time use in wearable fitness and mobility-monitoring applications; extension to clinical populations such as prosthetics, exoskeletons, and rehabilitation will require further validation beyond the healthy, normal-walking cohort tested here.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A Gait-Phase-Aware Adaptive Extended Kalman Filter for Drift-Free IMU Sensor Fusion and Gait Segmentation — Science Skim