Artificial intelligence for white matter hyperintensity segmentation: performance, determinants, and clinical implications.
Jinhua Hu, Zhihao Zhang, Peng Lei, Jupeng Zhang, Xiqi Zhu, Baosheng Li
Department of Radiology, Affiliated Hospital of Youjiang Medical University for Nationalities, Baise, China.
Key points
From the paper's conclusion- AI demonstrates promising performance for automated WMH segmentation, with U-Net-based architectures showing superior accuracy. However, substantial heterogeneity highlights the need for standardized imaging protocols and robust external validation. Future multicenter studies are essential to improve model generalizability and facilitate clinical translation.
Abstract
OBJECTIVE: White matter hyperintensities (WMH) are key neuroimaging markers of cerebral small vessel disease, associated with cognitive decline and stroke risk. Accurate quantification is essential yet manual segmentation is time-consuming and variable. We systematically evaluated AI performance for automated WMH segmentation across disease contexts and identified factors influencing model performance. METHODS: Following PRISMA guidelines, we searched PubMed, Embase, Web of Science, Scopus, and IEEE Xplore from database inception to February 3, 2026 (PROSPERO: CRD420261355769). Studies employing AI-based WMH segmentation and reporting Dice similarity coefficient (DSC) were included. A random-effects meta-analysis was conducted, along with subgroup analyses, meta-regression, sensitivity analyses, and publication bias assessment. RESULTS: 26 studies comprising 4,288 participants contributed to quantitative syntheses: 13 evaluated WMH segmentation in general cohorts, and 13 evaluated AD or CSVD-specific cohorts. In the general cohort meta-analysis, the pooled DSC was 0.78 (95% CI, 0.74-0.82). Disease-specific pooled DSC estimates were 0.75 for AD and 0.78 for CSVD. Exploratory meta-regression suggested an association between scanning parameters and DSC (p = 0.042), whereas magnetic field strength showed a borderline association (p = 0.052). CONCLUSION: AI demonstrates promising performance for automated WMH segmentation, with U-Net-based architectures showing superior accuracy. However, substantial heterogeneity highlights the need for standardized imaging protocols and robust external validation. Future multicenter studies are essential to improve model generalizability and facilitate clinical translation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Training AI Models for Automatic Segmentation and Quantification of White Matter Lesions Across Multiple Centres.Medicina (Kaunas, Lithuania) · 2026
- A Multi-Cohort nnU-Net for White Matter Hyperintensity Segmentation Across 2D and 3D FLAIR Acquisitions.medRxiv : the preprint server for health sciences · 2026
- Norms for Automatic Estimation of White Matter Hyperintensities Burden: LST-AI Service in neuGRID.Diagnostics (Basel, Switzerland) · 2026
- WHITE-Net: White matter HyperIntensities Tissue Extraction using deep learning network.Imaging neuroscience (Cambridge, Mass.) · 2026
- Regional correspondence between visual Fazekas ratings and AI-derived white matter hyperintensity burden in acute ischemic stroke: a retrospective cross-sectional studyBMC Neurology · 2026
- Artificial Intelligence in Cerebral Small Vessel Disease Imaging: A Study-Level Cross-Sectional Analysis of Validation Status and Clinical Applicability.Journal of imaging informatics in medicine · 2026