Preliminary evaluation of the TB-IGRA VIRCLIA® Monotest chemiluminescent interferon-gamma release assay: a comparative agreement study with QuantiFERON-TB Gold Plus.
Jose Mária Serrano, Maria Aguilera-Franco, Juan Francisco Gutiérrez-Bautista, Fernando Cobo, M J Olivares Duran, Antonio Sampedro-Padilla, F Ruiz, Jose Gutiérrez Fernández,
Microbiology Service, Virgen de las Nieves University Hospital, Granada, Spain. · Clinical Analysis and Immunology Service, Virgen de las Nieves University Hospital, Granada, Spain.
Key points
From the paper's conclusion- Conclusion The TB-IGRA VIRCLIA® Monotest showed a high overall qualitative agreement with QFT-Plus, particularly outside the borderline range.
Abstract
OBJECTIVES: We evaluated the qualitative and quantitative agreement of the novel chemiluminescent TB-IGRA VIRCLIA® Monotest with QuantiFERON®-TB Gold Plus (QFT-Plus) for detecting tuberculosis infection. METHODS: In this prospective comparative study, 226 consecutive samples submitted for routine tuberculosis infection testing were analyzed using the TB-IGRA VIRCLIA® Monotest and the QFT-Plus chemiluminescence immunoassay (CLIA). Agreement between the two tests was assessed by calculating the overall agreement, positive and negative percent agreement (PPA/NPA), Cohen's kappa (κ), Deming regression, and Bland-Altman analysis. An exploratory QFT-Plus-derived borderline range (0.20-0.70 IU/mL) was analyzed separately. Additional quantitative analyses were performed after excluding observations at the QFT-Plus upper quantification limit (10 IU/mL). RESULTS: Overall qualitative agreement was 92.9% (κ = 0.85; 95% confidence interval (CI), 0.79-0.92), with PPA of 90.1% (95% CI, 83.8-94.1) and NPA of 96.8% (95% CI, 91.1-98.9). Agreement was 94.25% for TB1 (κ = 0.885; 95% CI, 0.824-0.945) and 89.82% for TB2 (κ = 0.796; 95% CI, 0.718-0.875). In the borderline range, agreement decreased to 78.05% for TB1 (κ = 0.529; 95% CI, 0.289-0.769) and 69.05% for TB2 (κ = 0.316; 95% CI, 0.067-0.564), compared to 97.84 and 94.57%, respectively, for values outside this range. Deming regression slopes decreased from 3.085 to 0.811 for TB1 and from 3.146 to 0.926 for TB2 after excluding observations at the QFT-Plus upper quantification limit, with substantially narrower Bland-Altman limits of agreement. CONCLUSION: The TB-IGRA VIRCLIA® Monotest showed a high overall qualitative agreement with QFT-Plus, particularly outside the borderline range. Agreement decreased near the positivity threshold, particularly for TB2, supporting cautious interpretation and potential repeat or confirmatory testing of borderline results. Quantitative comparisons at high interferon-gamma (IFN-γ) concentrations were substantially influenced by the QFT-Plus upper quantification limit.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of QuantiFERON-TB Gold Plus results using ELISA and automated CLIA detection: a 39,000-sample real-world study.Microbiology spectrum · 2026
- A-199 High Diagnostic Accuracy of an Improved Fully Automated IGRA (LIAISON® QuantiFERON TB Gold Plus II) for Active TB and Low Risk ScreeningClinical Chemistry · 2026
- Evaluation of QIAreach QuantiFERON-TB for the diagnosis of Mycobacterium tuberculosis infection.Diagnostic microbiology and infectious disease · 2026
- Diagnostic Precision of QuantiFERON-TB Gold Plus Immunoassay Benchmarked Against Mycobacterial Cultivation and Nucleic Acid Amplification: A Retrospective Evaluation in 187 Patients.Microorganisms · 2026
- Comparative performance of IP-10-Based assays for immune detection of Mycobacterium tuberculosis infection: a cross-sectional evaluationFrontiers in Medicine · 2026
- Repeat Interferon γ Release Assay Use in US Community Healthcare Organizations.Open forum infectious diseases · 2026