Characterizing functional range of motion in two shoulder arthroscopy arm holders: a preliminary descriptive study
Savannah F. Prosperie, Michael A. Donohue, Madison S. Mach, Patrick K. Mescher, Shawn M. Gee
Key points
From the paper's conclusion- Clinical relevance This study is the first to report functional ROM for the Trimano and Spider2 arm holders.
Abstract
Introduction Two common arm holders utilized during shoulder arthroscopy include the Spider2 and the Trimano. The Trimano features a four-joint, manually controlled design, while the Spider2 uses a two-joint, battery-powered foot pedal system. Their differences in design may alter their range of motion (ROM) during shoulder surgery, however, functional descriptive ROM for these devices do not exist. Purpose To describe the ROM of the Trimano and Spider2 arm holders in standard arm positions for shoulder surgeries. Methods Three participants ( M = 2; age=32.3 ± 6.0years, height = 179.1 ± 16.6 cm, mass = 95.3 ± 30.7 kg), participated in this study. Three 2-D cameras captured motion in the sagittal, frontal, and transverse planes. Baseline ROM of the arm holders were captured. Subjects then completed shoulder forward flexion (FLEX), abduction (ABU) and external rotation (EXT) at baseline then with both arm holders. Dartfish360 was utilized to extract all ROM measures. Descriptive statistics were calculated for all ROM measurements. Results Arm holder baseline ROM was greater for the Trimano compared to the Spider2 across all planes. With participants, overall, the Spider2 permitted 31.13° more FLEX and 22.30° more ABU than the Trimano, while the Trimano allowed 9.93° more EXT. Conclusions The Trimano exhibited greater baseline ROM compared to the Spider2, but this did not translate when supporting the participants arms’ potentially due to the design of each device, although this was not assessed in this study. Future research should assess these arm holders in a larger population. Clinical relevance This study is the first to report functional ROM for the Trimano and Spider2 arm holders.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Looks like a surgeon? Impact of anthropometry on the kinematics of surgical novices: counterbalanced cross-over design study of minimally invasive surgery.Journal of robotic surgery · 2026
- A multi-rigid-body system model for thorax and upper-limb joint kinematics estimation designed for prosthetic users with trans-radial amputation.Journal of biomechanics · 2026
- Comparative Ergonomic Assessment of Microscopic, Endoscopic, and RobOtol®-Assisted Ear Surgery: A Prospective Pilot Study.Journal of clinical medicine · 2026
- Design and analysis of rehabilitation training mechanism based on upper limb rehabilitation movements.Acta of bioengineering and biomechanics · 2026
- Evaluation of shoulder-support exoskeletons during simulated laparoscopic surgery across representative shoulder postures.Ergonomics · 2026
- Arthroscopic Noninvasive Transtendon Double‐Pulley Suture‐Bridge Repair of Both‐Sided Partial‐Thickness Rotator Cuff TearsArthroscopy Techniques · 2026