Frontiers in Medicine

Rapid bedside estimation of enoxaparin activity using new Russell's viper venom-based and polybrene-modified viscoelastic assays: a prospective observational study

Daniel Olah, Endre Hajdu, Istvan Olah, Eva Molnar, Bela Fulesdi, Edina Nagy-Balo, Zsuzsanna Bereczky, Zsolt Olah

Observational

Key points

From the paper's conclusion
  • We previously described a viscoelastic approach based on clotting time (CT) ratios derived from CTs measured with and without liquid polybrene using a Russell's viper venom (RVV) assay.

Abstract

Background Rapid low-molecular-weight heparin activity assessment may be important in major bleeding or urgent surgery. Chromogenic anti-Xa assays remain the reference method, however, availability and turnaround time may limit their use. We previously described a viscoelastic approach based on clotting time (CT) ratios derived from CTs measured with and without liquid polybrene using a Russell's viper venom (RVV) assay. New RVV and integrated RVV/polybrene (RVH) assays have since emerged. Objectives To assess the new RVV-based configurations (RVV PB: RVV assay with manually added polybrene; RVH: integrated RVV/polybrene assay) for estimating enoxaparin activity and to explore CT ratio cut-offs for directional interpretation relative to anti-Xa thresholds of 0.3 and 0.6 IU/mL. Methods In this single-centre prospective observational study, 103 enoxaparin-treated cardiac intensive care patients were enrolled. Chromogenic anti-Xa activity served as the reference method. Using the ClotPro viscoelastic device, RVV PB and RVH CT ratios were defined as RVV CT divided by RVV CT with manually supplemented or integrated polybrene, respectively. Associations were examined using Spearman correlation, LOESS and Passing-Bablok regression with modified CUSUM tests. Receiver operating characteristic analyses informed exploratory, cohort-derived cut-offs; diagnostic accuracy and discordance asymmetry were assessed using 2 × 2 tables and exact two-sided McNemar tests. Results Passing-Bablok regression showed slopes close to 1.0 for both ratios (RVV PB:1.00, 95% CI 0.88–1.19; RVH:0.94, 95% CI 0.81–1.06). Exploratorily selected CT ratio cut-offs for discriminating anti-Xa levels below and above 0.3 and 0.6 IU/mL were 0.93, 1.20, and 1.50 for RVV PB, and 0.83, 1.00, and 1.30 for RVH. At the central cut-offs (RVV PB 1.20; RVH 1.00), ratios at or below the cut-off corresponded to anti-Xa ≤ 0.6 IU/mL in 95.0% and 98.2%, whereas ratios above it corresponded to anti-Xa > 0.3 IU/mL in 90.7% and 91.7%, respectively. Lower and upper cut-offs yielded one-sided information; discordances were asymmetric (all McNemar p ≤ 0.00149). Only 35.7% and 39.3% of patients with anti-Xa > 0.6 IU/mL exceeded the respective upper cut-offs. Conclusions Both configurations provided exploratory directional information about enoxaparin-associated anti-Xa activity; integrated RVH eliminated manual polybrene addition. The cut-offs and their accuracy require independent validation. Clinical use and effects on outcomes were not evaluated.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers