Limited transportability of a deep learning grading model for severe lumbar neural foraminal stenosis: external validation in two public cohorts
Huaguang Li, Hua Liu, Zhenshun Hu, Jingwei Chen, Zhiyuan Yang
Key points
From the paper's conclusion- We tested whether a locked lumbar magnetic resonance imaging (MRI) pipeline retained severe neural foraminal stenosis sensitivity and its development-defined safety operating point in an independent public cohort.
Abstract
Background Aggregate accuracy and discrimination can remain acceptable even when an artificial intelligence system misses severe disease at its applied decision rule. We tested whether a locked lumbar magnetic resonance imaging (MRI) pipeline retained severe neural foraminal stenosis sensitivity and its development-defined safety operating point in an independent public cohort. Methods A two-stage ConvNeXt-Tiny pipeline was developed using LumbarDISC sagittal T2-weighted examinations. It localized eight level-by-side targets from L2–L3 to L5–S1 and graded each as normal/mild, moderate, or severe. Target-specific temperature scaling was applied. Using five-fold out-of-fold predictions, we selected the highest severe-probability threshold that achieved the investigator-selected sensitivity target of 0.90. All components were frozen before one-time evaluation in a 395-patient internal test set and the independent 465-patient AISSLab cohort. The primary endpoint was target-level severe-class sensitivity in AISSLab. Confidence intervals used 2,000 patient-cluster bootstrap samples. Results AISSLab contributed 2,190 labeled targets, including 205 severe events. Argmax severe-class sensitivity decreased from 0.404 (61/151; 95% CI, 0.315–0.487) internally to 0.185 (38/205; 95% CI, 0.135–0.242). The external-minus-internal difference was −0.219 (95% CI, −0.314 to −0.114). External severe-class area under the receiver operating characteristic curve was 0.885, indicating that preserved ranking did not ensure sensitivity at the frozen decision rule. The safety threshold achieved 0.824 sensitivity (169/205), below its 0.90 development target, with a positive predictive value of 0.288 and referral rate of 0.268. Dataset-provided boxes increased argmax sensitivity by only 0.029. Target-domain temperature scaling slightly improved calibration but did not change argmax sensitivity and increased referral workload at the fixed threshold. Conclusion This pipeline showed limited internal severe-class sensitivity and a further decrease externally. Independent validation should assess intended operating points while accounting for reference-standard differences and incomplete labels.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Localization-Aware Multiscale Deep Learning for Lumbar Foraminal Stenosis in Multi-Scanner Sagittal MRI: A Leakage-Controlled EvaluationmedRxiv · 2026
- Evaluating Multimodal Vision Frontier Models for Grading Neuroforaminal Stenosis on Lumbar Spine MRIs.Global spine journal · 2026
- Automated Severity Grading of Lumbar Spinal Stenosis on Sagittal MRI Using a Two-Stage Deep Learning Framework with External Clinical Validation.Journal of imaging informatics in medicine · 2026
- Ordinal Deep Learning for Lumbar Foraminal Stenosis Grading on Sagittal MRI.Journal of imaging · 2026
- Ordinal Multi-Instance Learning for Automated Multi-Task Grading of Lumbar Degenerative Conditions on Sagittal MRI, with External ValidationmedRxiv · 2026
- Beyond Accuracy: Multi-Level Ordinal Assessment of Lumbar Spine Degeneration from Multiplanar MRI Using the RSNA 2024 (LumbarDISC) Dataset and Condition-Specific Models.Sensors (Basel, Switzerland) · 2026