Automated Severity Grading of Lumbar Spinal Stenosis on Sagittal MRI Using a Two-Stage Deep Learning Framework with External Clinical Validation.
Jackson Sieben, Nuno Cristino, Sandra Matias, Jorge Aikes Junior, Miguel Angel Guevara Lopez
Universidade Politécnica de Setúbal, Escola Superior de Tecnologia de Setúbal, DICE - ALGORITMI Lab, Campus da UNIPS, Estefanilha, Setúbal, 2910-761, Portugal. jackson.sieben@estsetubal.ips.pt. · Neurosurgery Department, Hospital da Luz Setúbal, EN 10, km 37, Setúbal, 2900-722, Portugal.
Key points
From the paper's conclusion- This study presents LSS-Net, a two-stage deep learning framework for automated grading of central canal stenosis using sagittal T2-weighted MRI.
Abstract
Lumbar spinal stenosis (LSS) is a prevalent degenerative condition and a major cause of disability in aging populations. Magnetic resonance imaging (MRI) is the preferred modality for assessment; however, severity grading remains inconsistent across readers and institutions, limiting reproducibility and complicating clinical decision-making. This study presents LSS-Net, a two-stage deep learning framework for automated grading of central canal stenosis using sagittal T2-weighted MRI. The first stage performs vertebral localization using a single-stage object detector, enabling standardized extraction of intervertebral regions of interest. The second stage applies a Swin Transformer-based classifier to predict stenosis severity (Normal/Mild, Moderate, Severe). The framework was developed using a multi-center dataset of 1,975 studies and evaluated on a held-out subset. Vertebral localization achieved 97.9% F1-score, while severity classification reached a weighted F1-score of 77.1%. Performance was highest for Normal/Mild and Severe classes, with reduced accuracy observed in Moderate cases, reflecting known diagnostic ambiguity. External clinical validation was conducted on an independent dataset using two expert readers. The model demonstrated substantial agreement with a neurosurgeon (accuracy 75.1%, κ = 0.73 ) and moderate agreement with a neuroradiologist (accuracy 51.0%, κ = 0.56 ), with inter-expert agreement in a comparable range. These findings suggest that LSS-Net may support more consistent and reproducible LSS grading. However, performance limitations in borderline cases and the restricted use of single-slice sagittal input highlight the need for further validation and extension to multi-sequence and multi-compartment analysis before clinical deployment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Limited transportability of a deep learning grading model for severe lumbar neural foraminal stenosis: external validation in two public cohortsFrontiers in Medicine · 2026
- Localization-Aware Multiscale Deep Learning for Lumbar Foraminal Stenosis in Multi-Scanner Sagittal MRI: A Leakage-Controlled EvaluationmedRxiv · 2026
- Evaluating Multimodal Vision Frontier Models for Grading Neuroforaminal Stenosis on Lumbar Spine MRIs.Global spine journal · 2026
- MRI-based severity classification of central canal stenosis using radiomics features and machine learning.Neuroradiology · 2026
- A Distributed Vision Transformer-Based Deep Learning Framework for Early Detection and Classification of Lumbar Disc Degeneration.Journal of visualized experiments : JoVE · 2026
- Ordinal Multi-Instance Learning for Automated Multi-Task Grading of Lumbar Degenerative Conditions on Sagittal MRI, with External ValidationmedRxiv · 2026