Frontiers in medicine

Application of fine-needle aspiration biopsy combined with multi-gene testing in the differential diagnosis of benign and malignant C-TIRADS 4 thyroid nodules.

Yingying Yuan, Jinhua Zhao, Yi Ren, Li Sun, Jiejie Chen

Department of Ultrasound, The Affiliated Huai'an No.1 People's Hospital of Nanjing Medical University, Huai'an, Jiangsu, China. · Department of Nuclear Medicine, The Affiliated Shanghai First People's Hospital of Nanjing Medical University, Shanghai, China.

Key points

From the paper's conclusion
  • FNAB combined with multi-gene testing significantly improves the sensitivity for differentiating benign from malignant thyroid C-TIRADS 4 nodules. Compared with FNAB combined with single-gene BRAFV600E testing, the multi-gene testing strategy offers improved sensitivity, particularly for detecting BRAFV600E-negative malignancies and FNAB-indeterminate nodules.

Abstract

AIM: To explore the clinical value of fine-needle aspiration biopsy (FNAB) combined with multi-gene testing (including BRAFV600E, TERT, RAS, and RET/PTC) in the differential diagnosis of benign and malignant thyroid Chinese Thyroid Imaging Reporting and Data System (C-TIRADS) 4 nodules and to compare its diagnostic performance with FNAB combined with single-gene testing. METHODS: A total of 650 patients (650 nodules) with thyroid nodules who visited our hospital between January 2021 and December 2024 were included in this study. All patients underwent ultrasound-guided FNAB and multi-gene testing (including BRAFV600E, TERT, RAS, and RET/PTC). Using postoperative pathological findings as the "gold standard," the diagnostic performance of ultrasound-guided FNAB and multi-gene testing for C-TIRADS 4 thyroid nodules was analyzed. The diagnostic efficacy of FNAB alone, each single-gene test alone, multi-gene testing alone, FNAB combined with each single-gene test, and FNAB combined with multi-gene testing in differentiating benign from malignant C-TIRADS 4 thyroid nodules was evaluated using receiver operating characteristic curves. RESULTS: Among the 650 thyroid nodules, 432 were malignant, and 218 were benign according to postoperative pathology reports. FNAB combined with multi-gene testing demonstrated improved sensitivity compared with FNAB alone, with a sensitivity of 91.0%, specificity of 76.15%, and accuracy of 86.0%. The AUC of the combined method was 0.836, which was significantly higher than that of FNAB alone (0.781) and multi-gene testing alone (0.806) (P < 0.05). In FNAB-indeterminate nodules, FNAB combined with multi-gene testing achieved a sensitivity of 88.24% and specificity of 89.19%. In the sensitivity analysis reclassifying Bethesda IV as FNAB-positive, FNAB alone achieved a sensitivity of 83.6%, specificity of 62.8%, and accuracy of 76.6%, confirming that the combined testing strategy provided incremental diagnostic value. CONCLUSION: FNAB combined with multi-gene testing significantly improves the sensitivity for differentiating benign from malignant thyroid C-TIRADS 4 nodules. Compared with FNAB combined with single-gene BRAFV600E testing, the multi-gene testing strategy offers improved sensitivity, particularly for detecting BRAFV600E-negative malignancies and FNAB-indeterminate nodules.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Application of fine-needle aspiration biopsy combined with multi-gene testing in the differential diagnosis of benign and malignant C-TIRADS 4 thyroid nodules — Science Skim