  • Contemporary molecular assays exhibit high sensitivity, reducing modeled residual risk to 3.5%-5.2% in resected indeterminate nodules. Because selective surgical verification may influence observed diagnostic accuracy estimates, particularly specificity, molecular results should be interpreted as conditional risk modifiers alongside clinical and sonographic findings.

Abstract

BACKGROUND: Indeterminate thyroid fine-needle aspirations (Bethesda III/IV) present diagnostic challenges due to a combination of biological ambiguity and technical limitations, precluding definitive histological evaluation of capsular or vascular invasion. We meta-analyzed commercial molecular triage assays in surgically verified cohorts. METHODS: Following PRISMA-DTA guidelines, PubMed, Embase, and Web of Science were searched from January 1, 2018, through the final search date of January 1, 2026. The target condition was an unharmonized composite disease-positive endpoint comprising malignancy and/or noninvasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP), according to the histopathological criteria reported in each primary study. Reitsma bivariate random-effects models pooled sensitivity and specificity. Likelihood ratios, diagnostic odds ratios, and 95% confidence intervals (CIs) were calculated via the delta method. Residual posttest disease probabilities were modeled across baseline risk tiers. RESULTS: Twenty-four publications yielded 38 cohorts (N = 5012 surgically confirmed nodules). Afirma GSC (k = 12, N = 1994) demonstrated pooled sensitivity of 91.2% (95% CI: 84.9%-95.0%), specificity of 78.1% (95% CI: 63.7%-87.8%), and negative likelihood ratio (NLR) of 0.11 (95% CI: 0.07-0.19). ThyroSeq v3 (k = 6, N = 685) showed sensitivity of 89.9% (95% CI: 84.5%-93.6%), specificity of 61.8% (95% CI: 54.2%-68.9%), and NLR of 0.16 (95% CI: 0.10-0.25). Multiplatform testing (MPTX; k = 5, N = 533) yielded sensitivity of 89.4% (95% CI: 81.2%-94.4%), specificity of 69.6% (95% CI: 57.1%-79.8%), and NLR of 0.15 (95% CI: 0.08-0.28). Legacy Afirma GEC and ThyroSeq v2 demonstrated sensitivities of 86.2% and 87.0%, specificities of 57.1% and 62.3%, and NLRs of 0.24 and 0.21, respectively. At 25.0% pretest risk, modeled residual disease probabilities were 3.5% (Afirma GSC), 5.2% (ThyroSeq v3), and 4.8% (MPTX). CONCLUSIONS: Contemporary molecular assays exhibit high sensitivity, reducing modeled residual risk to 3.5%-5.2% in resected indeterminate nodules. Because selective surgical verification may influence observed diagnostic accuracy estimates, particularly specificity, molecular results should be interpreted as conditional risk modifiers alongside clinical and sonographic findings. TRIAL REGISTRATION: PROSPERO Registration ID: CRD420261454380.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Comparative Diagnostic Accuracy of Molecular Assays for Indeterminate Thyroid Nodules Using Fine-Needle Aspiration Cytology Specimens: A Diagnostic Test Accuracy Systematic Review and Meta-Analysis — Science Skim