Direct visualization-assisted enteral stent placement in malignant colorectal obstruction: a case report.
Tianjie Han, Junshan Li
Departments of Hematology, Shandong Provincial Third Hospital, Shandong University, Jinan, China. · Department of Gastroenterology, Shandong Provincial Third Hospital, Shandong University, Jinan, China.
Key points
From the paper's conclusion- The EyeMax system enables real-time intraluminal visualization, facilitating safe and accurate guidewire placement in complex colorectal strictures. This technique may reduce reliance on blind manipulation and improve procedural safety.
Abstract
BACKGROUND: Malignant bowel obstruction caused by colorectal cancer is a common and serious clinical condition. Enteral stent placement is widely used as a palliative treatment or as a bridge to surgery. Accurate guidewire placement across stenotic segments remains technically challenging. CASE SUMMARY: A 39-year-old woman with sigmoid colon adenocarcinoma presented with abdominal pain and cessation of flatus and defecation for more than 20 days. Abdominal computed tomography demonstrated sigmoid colon cancer with intestinal obstruction. Colonoscopy revealed circumferential stenosis approximately 25 cm from the anus. A direct visualization system (EyeMax, Micro-Tech, Nanjing, China) was used through the biopsy channel and advanced across the stenotic segment under direct visualization. A Jagwire was successfully passed through the stricture via the EyeMax working channel. After withdrawal of the EyeMax, a self-expandable metallic stent was deployed over the guidewire under endoscopic visualization without fluoroscopy. The procedure was successful with immediate symptom relief. A delayed fecalith obstruction occurred and was effectively treated with endoscopic fragmentation. Following the procedure, the patient resumed passage of flatus and stool, and abdominal pain was significantly relieved. One month after stent placement, the patient underwent radical resection for sigmoid colon cancer without perioperative complications. During 1-year postoperative follow-up, the patient remained asymptomatic, with no evidence of recurrent intestinal obstruction, or tumor recurrence. CONCLUSION: The EyeMax system enables real-time intraluminal visualization, facilitating safe and accurate guidewire placement in complex colorectal strictures. This technique may reduce reliance on blind manipulation and improve procedural safety.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Successful Colonic Self-Expandable Metal Stent Placement Using a Rotatable Sphincterotome After Conventional Guidewire Insertion Failure: A Case Report.Cureus · 2026
- Fluoroscopy-guided colorectal stent placement for distal malignant colorectal obstruction: a retrospective single-center study.Diagnostic and interventional radiology (Ankara, Turkey) · 2026
- Efficacy of Preoperative Colonoscopy Following Self-Expandable Metallic Stent Placement in Patients with Obstructive Colorectal Cancer.Diseases of the colon and rectum · 2026
- 149 Malignant Large Bowel Obstruction in Patients With Colorectal Cancer: Assessment of Stent-Induced ChangesAmerican Journal of Clinical Pathology · 2026
- Prospective Multicenter Evaluation of a Novel Low‐Axial‐Force Colonic Stent for Malignant Colorectal ObstructionDEN Open · 2026
- Disposable digital catheter endoscope-assisted self-expandable metallic stent placement for malignant colonic obstruction: a retrospective cohort study.Surgical endoscopy · 2026