Surgical endoscopy

Disposable digital catheter endoscope-assisted self-expandable metallic stent placement for malignant colonic obstruction: a retrospective cohort study.

Daixing Chen, Jing Li, Xiaojun Yang, Zhaorong Tang, Fengliang Tian, Jia Deng, Jian Zeng

Department of Gastroenterology, Chongqing Hospital of Traditional Chinese Medicine, Chongqing, China. · CNU School Hospital, Chongqing Normal University, Chongqing, China.

Observational · n=30

Key points

From the paper's conclusion
  • E-SEMS improves procedural efficiency and eliminates intraprocedural fluoroscopic radiation exposure while achieving comparable safety and subsequent surgical outcomes compared with F-SEMS. This radiation-free minimally invasive strategy is a reliable alternative for the management of MCO.

Abstract

BACKGROUND AND AIMS: To investigate the efficacy and safety of a disposable digital catheter endoscope-assisted self-expandable metallic stent placement (E-SEMS) versus conventional fluoroscopy-guided self-expandable metallic stent placement (F-SEMS) in patients with malignant colonic obstruction (MCO). METHODS: This retrospective cohort study consecutively enrolled 30 patients diagnosed with MCO receiving self-expandable metallic stent placement between December 2024 and February 2026 at a tertiary hospital in Chongqing, China. Patients were retrospectively stratified into E-SEMS (n = 17) and F-SEMS (n = 13) group. The primary endpoints were procedural time and stent deployment time. Secondary endpoints included postoperative recovery, procedural complications and subsequent surgical outcomes. Multivariable regression analyses were performed to identify independent predictors of outcomes. RESULTS: The median procedural time (13.0 min vs. 24.0 min, P = 0.0015) and stent deployment time (5.2 min vs. 7.5 min, P = 0.0106) were significantly shorter in patients receiving E-SEMS compared with those undergoing F-SEMS. No differences were observed in postoperative recovery, complications and subsequent surgical outcomes. Multivariate regression revealed older age was independently associated with a lower probability of subsequent radical colectomy (P = 0.0335). After adjusting for confounders, stent modality exerted no independent influence on subsequent radical resection. CONCLUSIONS: E-SEMS improves procedural efficiency and eliminates intraprocedural fluoroscopic radiation exposure while achieving comparable safety and subsequent surgical outcomes compared with F-SEMS. This radiation-free minimally invasive strategy is a reliable alternative for the management of MCO.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers