Diagnostic accuracy of ChatGPT for 12-lead ECG-based localisation of ventricular ectopic foci prior to catheter ablation
Kadri Murat Gürses, Hüseyin Tezcan, Muhammed Ulvi Yalçin, Halil Özalp, Abdullah Tunçez, Yasin Özen
Selçuk University
Key points
From the paper's conclusion- The duration of the procedure and the acute ablation success rate (96%) were unaffected by the accuracy of ChatGPT.
Abstract
Background Precise pre-procedural localisation of ventricular ectopic (VE) foci shortens mapping time, reduces fluoroscopy, and improves ablation success. Large language models such as ChatGPT offer instant, free-text clinical support; however, their accuracy in ECG-based VE localisation is unknown. Methods In this single-centre pilot study, we assessed the diagnostic accuracy of ChatGPT in 50 consecutive adults (average age: 43 ± 14 years; 58% women) scheduled for first-time VE ablation. ChatGPT served as the index test, and invasive electroanatomical mapping during the ablation served as the reference standard. A blinded electrophysiologist converted each index 12-lead ECG into a structured textual description of QRS morphology. ChatGPT-4o (temperature 0.2) was then tasked with assigning one of five anatomical origins (RVOT, LVOT, papillary muscle, fascicular, and epicardial). Predictions were compared with electro-anatomical mapping during catheter ablation, and agreement was measured using Cohen’s κ (κ). Results Electro-anatomical mapping identified 30 RVOT, 11 LVOT, 4 papillary, 1 fascicular, and 4 epicardial foci. ChatGPT correctly localised 17/50 cases (34%), yielding an overall Cohen’s κ of −0.02 (95% CI –0.18 to 0.14). Sensitivity/specificity was 40%/55% for the RVOT and 36%/62% for the LVOT; no fascicular or epicardial origins were correctly predicted. The performance of ChatGPT did not differ based on the presence of structural heart disease ( p = 0.43). The duration of the procedure and the acute ablation success rate (96%) were unaffected by the accuracy of ChatGPT. Conclusion Freetext querying of ChatGPT failed to provide clinically meaningful VE localisation, performing no better than chance and markedly below published ECG-based algorithms. This likely reflects the model’s lack of domain-specific training and its reliance on purely text-based reasoning without direct access to ECG signals. Current general-purpose language models should not be relied upon for procedural planning in VE ablation; future work must integrate multimodal training and domain-specific optimisation before LLMs can augment electrophysiology practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial intelligence vs. cardiologists for PVC localization - still a long way to goEuropean Heart Journal · 2026
- Large Language Model‐Based Localization of Premature Ventricular Contraction Origins: A Retrospective Diagnostic Accuracy StudyJournal of Cardiovascular Electrophysiology · 2026
- Artificial intelligence-based automated interpretation of images of electrocardiograms: development and multinational validation of ECG-GPTEuropean Heart Journal - Digital Health · 2026
- LEAP-LLM: Preserving lead-time structure for question-conditioned ECG interpretationarXiv · 2026
- Multimodal large language models demonstrate consistently low accuracy for 12-lead electrocardiogram interpretation: a 599-case benchmark studyEuropean Heart Journal · 2026
- Machine Learning‐Based Classification of Right and Left Ventricular Outflow Tract Premature Ventricular ContractionsAnnals of Noninvasive Electrocardiology · 2026