◆ Journal of Cardiovascular Electrophysiology2026-08-01· Medicine

Large Language Model‐Based Localization of Premature Ventricular Contraction Origins: A Retrospective Diagnostic Accuracy Study

Kazuhisa Matsumoto, Yuya Fujisaki, Syunta Higuchi, Masataka Narita, Wataru Sasaki, Tsukasa Naganuma, Naomichi Tanaka, Daisuke Kawano, Kei Matsumoto, Wataru Yoshino, Yoshifumi Ikeda, Ritsushi Kato, Hitoshi Mori

原始摘要(英文原文)· Original abstract
BACKGROUND: Accurate localization of premature ventricular contraction (PVC) origin from 12-lead electrocardiography (ECG) is important for procedural planning in catheter ablation. Although convolutional neural network (CNN)-based models have shown promising diagnostic performance, they require task-specific training and remain limited in interpretability. We evaluated whether large language model (LLM)-based ECG image interpretation could perform binary left-versus-right PVC origin localization from 12-lead ECG images while providing a traceable diagnostic process. METHODS: We retrospectively studied 157 patients who underwent successful catheter ablation of PVCs or idiopathic ventricular tachycardia. ECG images were classified as RIGHT-origin (n = 103) or LEFT-origin (n = 54) according to the final successful ablation site. Three approaches were compared: a CNN-based baseline model, an LLM-based one-shot approach, and an LLM-based staged extraction framework with deterministic rule-based integration. Performance was evaluated across five independent seeds using positive predictive value (PPV), negative predictive value (NPV), recall, and PPV + NPV. RESULTS: The CNN-based baseline model achieved a PPV of 0.546 ± 0.058 and an NPV of 0.793 ± 0.047, with area under the curve values ranging from 0.595 to 0.730. The staged extraction framework generated a continuous rule-based score with discrimination numerically comparable to the CNN-based model (AUC 0.720 ± 0.045 vs. 0.712 ± 0.054). A stricter threshold, determined from training data, increased PPV at the expense of recall and warrants prospective external validation of this operating point. CONCLUSIONS: LLM-based staged extraction demonstrated the potential to achieve binary left-versus-right PVC origin localization from 12-lead ECG images while providing a traceable stepwise diagnostic process. The continuous rule-based score showed discrimination numerically comparable to the CNN-based model, and the strict threshold-determined using training data-identified a potential high-PPV operating point that requires prospective external validation.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Large Language Model‐Based Localization of Premature Ventricular Contraction Origins: A Retrospective Diagnostic Accuracy Study — 科研速览 Science Skim