A novel approach to TDS estimation in desalination systems using differential pressure sensing
Prashant Parmar, Ali M. Alasmari, Arvind Yadav, Mohammed Almaz, Nidal A. Ghizawi, Thomas Altmann, Ratul Das
Schneider Electric (Germany) · King Abdullah University of Science and Technology
Abstract
Total dissolved solids (TDS) measurements are crucial for desalination processes, as they affect water quality, operational efficiency, and environmental sustainability. This paper presents a novel solution that uses a differential pressure (DP) transmitter to measure TDS in desalination plants. The proposed method uses a dual-leg setup, with one leg filled with distilled water as a reference and the other with saline water (sample). The DP transmitter measures the pressure difference between the two legs, which indicates the density difference caused by dissolved salts in the sample water. The conversion of pressure difference to density difference and subsequently to TDS offers high accuracy, with an uncertainty of ±521 mg/L (about 1.3%), a significant improvement over existing laboratory measurements used in the desalination plant, which show a variance ranging from 2.7% to 20%. This system enhances operational efficiency and reduces the time required for TDS measurement compared with traditional laboratory methods.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Saudi Water Authority (SWA) Strategies for raising the total dissolved solids (TDS) concentration of water produced and transported from desalination plants: Advantages and challengesCambridge Materials Water · 2026
- Transforming Agricultural Drainage into a Sustainable Water Resource for Agricultural Reuse: Insights from Al-Ahsa OasisSustainability · 2026
- Use of a sampler to collect spent dialysate in hemodialysis: a technical note.Journal of nephrology · 2026
- Auditable Clean-in-Place Decision Support from Routine SWRO SCADA: Selecting Differential-Pressure Recovery and Falsifying a Per-CIP-Reset Trigger.Membranes · 2026
- Cumulative Spectroscopic Detection for Taylor Dispersion Analysis of NanoparticlesAnalytical Chemistry · 2026
- In situ measurement of sludge density using reciprocating rotation and pulse-width varianceMeasurement Science and Technology · 2026