A multi-indicator and multi-device coordinated siting strategy for enhancing transient safety support capability in weak sending-end grids with renewable energy stations
Fang Liu, Guiqi Liang, Qian Chen, Yongjie Zhang, Yangbin Zeng, Fan Xie
Key points
From the paper's conclusion- The results show that the proposed strategy can effectively improve the steady-state performance and suppress transient voltage fluctuations of the power grid.
Abstract
Large-scale long-distance transmission of renewable energy leads to typical weak sending-end characteristics in power grids, where transient disturbances easily cause voltage instability and large-scale tripping of renewable energy units. To address the defects of one-sided indicators and insufficient multi-dimensional collaborative frameworks in conventional siting methods, this paper proposes a coordinated siting strategy for multiple reactive power support devices. Firstly, a multi-dimensional voltage safety evaluation system is established, including the multiple renewable energy stations short circuit ratio, transient voltage fluctuation index and reactive power compensation trajectory sensitivity index. Secondly, considering device characteristics and grid hierarchy, a differentiated deployment scheme for synchronous condensers and static synchronous compensators (STATCOM) is formulated. Furthermore, the entropy weight method and Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) method are integrated to build a siting decision model to resolve conflicts among multiple indicators. Multi-scenario time-domain simulations are carried out based on an actual renewable energy base model. The results show that the proposed strategy can effectively improve the steady-state performance and suppress transient voltage fluctuations of the power grid. It outperforms conventional single-device schemes and improper siting schemes under various fault conditions, thereby demonstrating the effectiveness of the proposed method.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Coordinated Synchronous Condensers and Static Var Generator Planning Considering Unit Commitment-Dependent Multiple Renewable Energy Station Short-Circuit Ratio ConstraintsEnergies · 2026
- Dynamic Assessment of Voltage Regulation Capacity in High-Penetration PV and Electrochemical Energy Storage Distribution Networks Considering Response Delay and Source–Load CorrelationComputation · 2026
- Capacity and Operation Planning of Distributed Photovoltaic and Energy Storage with Screening-Based Site Assessment and Coordinated Reactive Power Compensation in Distribution NetworksEnergies · 2026
- Research on Low Voltage Ride through Capability of Offshore Wind Farm Grid Integration Based on Dynamic Reactive Power CompensationJournal of Engineering Research and Reports · 2026
- A risk assessment method of multi-form transient voltage stabilities for high-proportion renewable energy sending-end power gridsInternational Journal of Electrical Power & Energy Systems · 2025
- Operating-State-Aware Hydropower Dynamic Support Index and Hierarchical Coordinated Voltage Control for Renewable-Rich Active Distribution NetworksEnergies · 2026