Detecting temporal clinical change in sequential chest radiography reports: a multi-model and multi-prompt evaluation of large language models.
Ertürk Erdağı
Department of Computer Engineering, Istanbul Medeniyet University, İstanbul, Türkiye.
Key points
From the paper's conclusion- These findings demonstrate that Large Language Models hold substantial promise for temporal clinical reasoning in sequential radiology reports, and that performance depends not only on model architecture but also on prompt strategy and the class being evaluated.
Abstract
BACKGROUND: Radiology reports contain critical information for monitoring patients' clinical progress and evaluating treatment outcomes. Sequential radiological images are particularly valuable, providing not only current findings but also comparative assessments against previous reports. Automatically detecting temporal changes between free-text reports remains a significant challenge in Natural Language Processing. METHODS: This study evaluated the performance of Large Language Models in detecting temporal novelty using the LUNGUAGE dataset, which contains sequential chest radiography reports. The comparative multi-model and multi-prompt evaluation was carried out on a fixed, class-stratified subset of 1,500 of these examples. Seven language models from OpenAI, Anthropic, and Google Gemini were tested across five prompt strategies: zero-shot, few-shot, structured reasoning, memory-augmented, and temporal graph prompting. Each model classified target findings as new, improved, worsened, stable, or resolved by evaluating current and previous reports together. Performance was measured using accuracy, macro-F1, weighted-F1, and class-based metrics. The "new" class was analyzed separately due to its clinical importance. Model errors were categorized into clinically interpretable types, including missed new findings, missed resolved findings, temporal errors, and change direction errors. Bootstrap confidence intervals and paired McNemar significance tests assessed performance uncertainty. RESULTS: GPT-4.1 emerged as the top-performing model. Its few-shot prompt strategy achieved the best results: 0.8369 accuracy, 0.7888 macro-F1, 0.8322 weighted-F1, and 0.5385 recall for the "new" class. CONCLUSION: These findings demonstrate that Large Language Models hold substantial promise for temporal clinical reasoning in sequential radiology reports, and that performance depends not only on model architecture but also on prompt strategy and the class being evaluated.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Insufficient reporting quality in large language model studies in the field of radiologyInsights into Imaging · 2026
- CPVB-RG: Cross-Prior Visual Bridging for Prior-Aware Chest X-Ray Report GenerationarXiv · 2026
- Clinical selectivity and failure modes of automated chest radiograph report evaluation metrics: a cross-dataset analysis of ReXErr-v1 and RadEvalXmedRxiv · 2026
- Large Language Model-Assisted Cleaning of Report-Derived Labels in a Large-Scale Chest CT Dataset.Journal of medical systems · 2026
- A review of longitudinal radiology report generation: Dataset composition, methods, and performance evaluation.Medical image analysis · 2026
- Multimodal Error Detection in Chest X-ray Reports: A Large Language Model Reading Image EvidencearXiv · 2026