Expanding indications for transcatheter aortic valve implantation: time for valve-in-valve in mechanical prosthesis? A systematic review and meta-analysis.
Julio Ruiz-Ruiz, Akash Jain, Mario García Gómez, Alexander Stepanenko, Filippo Pensotti, Marcelo Rodríguez, Carlos Real, Carlos Cortés Villar,
Cardiology Department, University Clinic Hospital of Valladolid, Spain. · Centro Nacional de Investigación Cardiovascular (CNIC), Madrid, Spain.
Key points
From the paper's conclusion- Mechanical aortic valves show excellent long-term durability with low reintervention rates. Nevertheless, valve-related complications, mainly bleeding and thromboembolism, suggest a small but clinically relevant population in whom redo surgery may carry substantial risk, providing epidemiological context for emerging Valve in Mechanical Valve strategies.
Abstract
AIMS: Following the recent first-in-human experience of Valve in Mechanical Valve (ViMech), interest has emerged in understanding how frequently such an approach might be required in clinical practice. We performed an exploratory meta-analysis to characterize the long-term burden of valve-related complications and reintervention after mechanical aortic valve replacement. METHODS: Systematic literature search identified studies reporting outcomes of the five most used mechanical aortic valve models (Medtronic/ATS, St. Jude, Carbomedics, Bicarbon, On-X). Descriptive analysis and random-effects meta-analysis assessed late all-cause and valve-related mortality and complications (bleeding, thromboembolism, valve thrombosis, endocarditis, paravalvular leak, reintervention), expressed per 100 patient-years. RESULTS: Thirty-two studies encompassing 24,960 patients undergoing mechanical valve replacement were assessed. Isolated mechanical aortic valve replacement was reported in all 32 studies (13,890 patients; 98,987 patient-years; mean follow-up 7.1 years); mean age at implantation was 57.9 years (95% CI 56.3-59.6) and 43% (38-49) were female. Pooled all-cause mortality was 2.39 per 100 patient-years (95% CI 1.92-2.99) and valve-related mortality was 0.55 (0.41-0.73) per 100 patient-years. Bleeding (0.22 [0.16-0.30]) and thromboembolic events (0.18 [0.12-0.25]) were the leading causes of valve-related death. Thromboembolic events (0.94 [0.77-1.14]) and bleeding (0.85 [0.65-1.10]) were the most frequent non-fatal complications, considerably more common than reintervention (0.36 [0.28-0.48] per 100 patient-years). All-cause mortality and complication rates were broadly similar across valve models. CONCLUSIONS: Mechanical aortic valves show excellent long-term durability with low reintervention rates. Nevertheless, valve-related complications, mainly bleeding and thromboembolism, suggest a small but clinically relevant population in whom redo surgery may carry substantial risk, providing epidemiological context for emerging Valve in Mechanical Valve strategies. SYSTEMATIC REVIEW REGISTRATION: https://www.crd.york.ac.uk/PROSPERO/view/CRD420251002419, identifier CRD420251002419.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mechanical versus bioprosthetic aortic valves: the ultimate trade-offs every middle-aged patient should know.Journal of cardiothoracic surgery · 2026
- One-Year Outcomes of Myval Versus Contemporary Transcatheter Heart Valves in Severe Aortic Stenosis: A Systematic Review and Meta-Analysis.Cardiology in review · 2026
- Outcomes after conversion from mechanical to bioprosthetic valves for anticoagulation-related complications.JTCVS open · 2026
- Valve‐in‐Valve Transcatheter Mitral Valve Replacement Versus Redo Surgical Mitral Valve Replacement: Meta‐Analysis of Early and Late OutcomesJournal of the American Heart Association · 2026
- Updated systematic review and meta-analysis comparing Myval versus Sapien 3 transcatheter heart valves in severe aortic stenosis: focus on early and one-year mortality.Acta cardiologica · 2026
- Ten-year reintervention-free survival after surgical aortic valve replacement for different prosthetic aortic valve models: comparison using real-world data from the Netherlands Heart Registration.Interdisciplinary cardiovascular and thoracic surgery · 2026