科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Interdisciplinary cardiovascular and thoracic surgery2026-08-31

Ten-year reintervention-free survival after surgical aortic valve replacement for different prosthetic aortic valve models: comparison using real-world data from the Netherlands Heart Registration.

Hector W L de Beaufort, Maaike M Roefs, Edgar J Daeter, Wilson W L Li, Wim Jan P van Boven, Niels P van der Kaaij, Dennis van Veghel, Cardiothoracic Surgery Registration Committee of the Netherlands Heart Registration

一句话结论 · In one sentence

Differences in ten-year outcomes after SAVR were observed for the different prosthetic aortic valve models that were used in the Netherlands Heart Registration, especially for biological prosthetic aortic valve models, with survival varying from 50.7% to 72.6% and freedom from reintervention from 90.5% to 99.3%.

原始摘要(英文原文)· Original abstract
OBJECTIVES: To compare long-term outcomes across different models of mechanical and biological aortic valve prostheses after surgical aortic valve replacement (SAVR) in the Netherlands. METHODS: Data from the Netherlands Heart Registration on isolated, primary SAVR procedures performed from 2007 to 2018 in adult patients were used, excluding active endocarditis. Ten-year survival and freedom from valve-related reintervention were estimated for models that were implanted >200 times, using Cox proportional hazards models for survival and Fine and Gray's models with death as the competing-event for freedom of reintervention. RESULTS: For 11,139 patients treated with a biological prosthetic aortic valve, ten-year survival was highest for the Perimount Magna Ease (72.6%) and Epic (70.0%), and significantly lower for the Perimount Magna (65.1%), Trifecta (63.1%), Perimount (61.4%), Freedom Solo (51.5%), and Mitroflow (50.7%). Ten-year freedom from reintervention was highest for the Perimount Magna (99.3%), and significantly lower for the Perimount Magna Ease (98.2%), Perimount (98.2%), Epic (97.3%), Trifecta (96.8%), Freedom Solo (93.2%) and Mitroflow (90.5%). For 2,123 patients treated with a mechanical prosthetic aortic valve, ten-year survival was highest for the Regent (91.2%) and not significantly different for the Open Pivot (89.2%), Slimline (87.5%), HP (87.3%) and significantly lower for the Carbomedics Reduced (87.0%). Ten-year freedom from reintervention was highest for the Carbomedics Reduced (97.1%), not significantly different for the Open Pivot (96.1%), Slimline (96.5%), Regent (95.9%), and significantly lower for the HP (94.9%). CONCLUSIONS: Differences in ten-year outcomes after SAVR were observed for the different prosthetic aortic valve models that were used in the Netherlands Heart Registration, especially for biological prosthetic aortic valve models, with survival varying from 50.7% to 72.6% and freedom from reintervention from 90.5% to 99.3%.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Ten-year reintervention-free survival after surgical aortic valve replacement for different prosthetic aortic valve models: comparison using real-world data from the Netherlands Heart Registration. — 科研速览 Science Skim