Frontiers in cardiovascular medicine

Esophageal deviation using the transesophageal echocardiography probe during atrial fibrillation radiofrequency ablation: a prospective observational study.

Fabien Squara, Sok-Sithikun Bun, Camille Verdan, Didier Scarlatti, Emile Ferrari

Service de Cardiologie, Centre Hospitalier Universitaire de Nice, Nice, France.

Observational

Key points

From the paper's conclusion
  • TEE probe-guided esophageal deviation appears as a practical and effective technique for reducing esophageal proximity and thermal exposure during AF ablation, offering a valuable safety enhancement where dedicated tools are unavailable.

Abstract

BACKGROUND: Esophageal injury is a recognized complication of atrial fibrillation (AF) radiofrequency ablation, during pulmonary vein isolation (PVI) or posterior wall ablation. Mechanical esophageal deviation has emerged as a promising preventive strategy, however, commercially available deviation tools are not accessible outside the United States. We evaluated the feasibility and effectiveness of using the transesophageal echocardiography (TEE) probe-readily available in many electrophysiology labs-for esophageal deviation during AF ablation. METHODS: In this prospective observational study, patients undergoing PVI ± additional atrial ablation for AF were treated using esophageal deviation (Dev-Group) or using standard care (Std-Group) depending on the operating electrophysiologist. In the Dev-Group, esophageal position was identified using barium ingestion, and the TEE probe was manipulated to achieve maximal displacement away from posterior pulmonary vein (PV) ostia. Deviation of esophageal trailing edge >10 mm from PV was defined as successful. Esophageal temperature was monitored in both groups using a multi-sensor probe. RESULTS: Sixty patients (30 per group; 60 PV pairs each) were included. In the Dev-Group, 78% (47/60) of PV pairs achieved >10 mm esophageal separation vs. 30% (18/60) at baseline (p < 0.001); PV-esophagus overlap dropped from 52% (31/60) at baseline to 2% (1/60) after deviation (p < 0.001). Temperature rises >38 °C were observed during 2 radiofrequency applications in the Dev-Group versus 75 in the Std-Group (p < 0.001). No esophageal injuries were reported. CONCLUSION: TEE probe-guided esophageal deviation appears as a practical and effective technique for reducing esophageal proximity and thermal exposure during AF ablation, offering a valuable safety enhancement where dedicated tools are unavailable.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Esophageal deviation using the transesophageal echocardiography probe during atrial fibrillation radiofrequency ablation: a prospective observational study — Science Skim