Transoesophageal echocardiography as complementary imaging during pulsed field ablation of atrial fibrillation: a practical step-by-step approach.
Federico Marchini, Matteo Arzenton, Federica Frascaro, Luca Canovi, Michele Malagù, Francesco Vitali, Sofia Meossi, Laura Rotondo,
Cardiology Unit, Azienda Ospedaliero Universitaria di Ferrara, Via Aldo Moro 8, Ferrara 44124, Italy.
Key points
From the paper's conclusion- TOE should be considered a complementary imaging modality during fluoroscopy- and angiography-guided PFA rather than a replacement for these techniques. Its principal contribution is real-time visualization of soft-tissue anatomy, transseptal puncture, catheter-tissue relationships, and immediate post-procedural complications. Prospective studies are required to quantify its incremental clinical value.
Abstract
AIMS: Transoesophageal echocardiography (TOE) provides real-time soft-tissue anatomical information during pulsed field ablation (PFA) of atrial fibrillation. This focused technical report describes a standardized workflow in which TOE complements, rather than replaces, fluoroscopic, and angiographic guidance throughout the procedure. TECHNIQUE: The workflow is organized into four consecutive phases: pre-procedural assessment, transseptal puncture, ablation-catheter configuration and positioning at the pulmonary vein ostia, and post-procedural assessment. Pre-procedural TOE focuses on exclusion of left atrial appendage thrombus, definition of pulmonary vein anatomy, assessment of the interatrial septum, and baseline evaluation for pericardial effusion. During transseptal access, orthogonal bicaval and short-axis views support puncture-site selection and continuous visualization of septal tenting, while fluoroscopy remains integral to guidewire and transseptal-system manipulation. During ablation, TOE complements fluoroscopic/angiographic guidance by depicting catheter configuration and its relationship with the pulmonary vein ostia and adjacent soft-tissue structures. At procedure completion, TOE is used to assess the iatrogenic interatrial septal defect and to exclude new pericardial effusion. CONCLUSION: TOE should be considered a complementary imaging modality during fluoroscopy- and angiography-guided PFA rather than a replacement for these techniques. Its principal contribution is real-time visualization of soft-tissue anatomy, transseptal puncture, catheter-tissue relationships, and immediate post-procedural complications. Prospective studies are required to quantify its incremental clinical value.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Atrial fibrillation ablation using real-time three-dimensional transesophageal echocardiography as the primary intraprocedural imaging modality: a single-center feasibility studyJournal of Interventional Cardiac Electrophysiology · 2026
- Impact of pulsed field ablation for atrial fibrillation on left atrial remodeling at mid – term follow -upEuropean Heart Journal · 2026
- Pulsed field ablation versus conventional thermal ablation for atrial fibrillation: a systematic review and meta-analysisEuropean Heart Journal · 2026
- Use of 3D Intracardiac Echocardiography for Concomitant Ablation of Atrial Fibrillation and Left Atrial Appendage Closure: A Step by Step Guide.Journal of cardiovascular electrophysiology · 2026
- Guidewire entrapment in pulmonary veins during pulsed field ablation of atrial fibrillation: A case seriesHeartRhythm Case Reports · 2026
- Pulsed field ablation for the interventional treatment of atrial fibrillation: a scientific statement of the European Heart Rhythm Association of the European Society of Cardiology, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, the Latin American Heart Rhythm Society, and the Canadian Heart Rhythm SocietyEP Europace · 2026