Frontiers in cardiovascular medicine

Polymeric mitral valve replacement in rheumatic heart disease: hemodynamic and early clinical outcomes from a dedicated sub-analysis of the India Surgical Trial.

J Ryan Stanfield, Isaac George, Brian Whisenant, Anil Jain, Dasari Prasada Rao, Kaushal Pandey

University of Utah, Salt Lake City, UT, United States. · New York Presbyterian Hospital-Columbia University Irving Medical Center, New York, NY, United States.

Trial · n=67

Key points

From the paper's conclusion
  • The polymeric valve demonstrated an acceptable safety profile and excellent hemodynamic stability at one-year. Further studies are needed to confirm durability and study anticoagulation reduction. Polymeric valves may be a promising option for patients with RHD.

Abstract

BACKGROUND: Rheumatic heart disease (RHD) is a leading cause of cardiovascular morbidity in low- and middle-income countries (LMICs), disproportionately affecting young patients and women of childbearing age. Current valve options-mechanical and bioprosthetic-result in significant challenges in these populations, including the need for intensive anticoagulation monitoring or accelerated structural deterioration. This study evaluates a novel polymeric heart valve designed to overcome these limitations. METHODS: The India Mitral Surgical Trial (CTRI/2023/02/049837) was a prospective, multicenter, single-arm trial involving 67 adult patients requiring mitral valve replacement. Patients were implanted with the polymer surgical mitral valve and followed for one-year with safety and hemodynamic assessments. Vitamin K antagonists were administered for a target INR of 2.5. This subgroup analysis focuses on patients with RHD. RESULTS: The RHD subgroup, included 49 patients with a mean age of 39 years, of whom 33 (67%) were female. The trial achieved 100% technical success defined as successful implantation of the study valve with immediate satisfactory valve function and no intraoperative valve-related complications. At one-year, all-cause mortality for the RHD subgroup was 10.2% with no valve-related deaths and no incidence of structural valve deterioration or valve reintervention. The mitral inflow gradient decreased from 9.9 ± 5.1 mmHg at baseline to 4.2 ± 1.5 mmHg at discharge and 4.4 ± 1.7 mmHg at 1 year while the echo defined effective orifice area increased from 0.9 ± 0.5 cm2 at baseline to 1.6 ± 0.6 cm2 at discharge and remained stable at 1.5 ± 0.4 cm2 at 1 year. Thromboembolic events were comparable to commercial valves in the setting of a high percentage of patients requiring anticoagulation for preoperative atrial fibrillation. CONCLUSION: The polymeric valve demonstrated an acceptable safety profile and excellent hemodynamic stability at one-year. Further studies are needed to confirm durability and study anticoagulation reduction. Polymeric valves may be a promising option for patients with RHD.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Polymeric mitral valve replacement in rheumatic heart disease: hemodynamic and early clinical outcomes from a dedicated sub-analysis of the India Surgical Trial — Science Skim