Key points

From the paper's conclusion
  • Tendyne V-i-R procedures are technically feasible, effective, and safe in selected high-risk patients with recurrent MR. Ring size thresholds identified may guide patient selection and procedural planning in future interventions.

Abstract

OBJECTIVES: Mitral regurgitation (MR) is commonly treated with ring-based annuloplasty. In case of recurrent MR, re-do operations are often denied due to high risk. Transcatheter valve-in-ring (V-i-R) procedures offer an alternative. This study assessed the feasibility and outcomes of using the transapical, repositionable Tendyne valve for off-label mitral V-i-R procedures, as an alternative to balloon-expandable valves like SAPIEN, which face limitations such as paravalvular leakage and LVOT obstruction. METHODS: The TEND-RING registry is a retrospective, international study with prospective follow-up, including 16 high-risk patients from eight European centers who underwent Tendyne V-i-R procedures between 2017 and 2024. Procedural, 30-day, and long-term outcomes were analyzed. RESULTS: Patients were elderly (median age 79.5), predominantly male (81%), with significant comorbidities (STS Risk of Mortality 5.6%, 4.4-7.2%) and severe MR (3 + /4 +). Procedural success was 100%, with no LVOT obstruction or device embolization. MR was reduced to mild or none in all patients. 30-day mortality was 6.3%. Over a median 11-month follow-up, five deaths occurred (31.3%), three from cardiovascular causes (18.75%). Surviving patients showed sustained MR reduction and improved symptoms (89% in NYHA I/II). Ring size analysis suggested a minimum of 36 mm for rigid/semi-rigid rings, while flexible bands allowed successful implantation in sizes as small as 30 mm. CONCLUSIONS: Tendyne V-i-R procedures are technically feasible, effective, and safe in selected high-risk patients with recurrent MR. Ring size thresholds identified may guide patient selection and procedural planning in future interventions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers