Transapical mitral valve-in-ring implantation: Results of the real-world European Tendyne valve-in-ring registry.
Julian Maier, Hendrik Ruge, Markus Krane, Sabine Bleiziffer, Kai P Friedrichs, Efstratios I Charitos, Markus Schönburg, Elmar W Kuhn,
Department of Cardiology, Kepler University Hospital, Krankenhausstraße 9, 4020, Linz, Austria. · Department of Cardiovascular Surgery, TUM School of Medicine and Health, Technical University of Munich, TUM University Hospital German Heart Center, Lazarettstraße 36, 80636, Munich, Germany.
Key points
From the paper's conclusion- Tendyne V-i-R procedures are technically feasible, effective, and safe in selected high-risk patients with recurrent MR. Ring size thresholds identified may guide patient selection and procedural planning in future interventions.
Abstract
OBJECTIVES: Mitral regurgitation (MR) is commonly treated with ring-based annuloplasty. In case of recurrent MR, re-do operations are often denied due to high risk. Transcatheter valve-in-ring (V-i-R) procedures offer an alternative. This study assessed the feasibility and outcomes of using the transapical, repositionable Tendyne valve for off-label mitral V-i-R procedures, as an alternative to balloon-expandable valves like SAPIEN, which face limitations such as paravalvular leakage and LVOT obstruction. METHODS: The TEND-RING registry is a retrospective, international study with prospective follow-up, including 16 high-risk patients from eight European centers who underwent Tendyne V-i-R procedures between 2017 and 2024. Procedural, 30-day, and long-term outcomes were analyzed. RESULTS: Patients were elderly (median age 79.5), predominantly male (81%), with significant comorbidities (STS Risk of Mortality 5.6%, 4.4-7.2%) and severe MR (3 + /4 +). Procedural success was 100%, with no LVOT obstruction or device embolization. MR was reduced to mild or none in all patients. 30-day mortality was 6.3%. Over a median 11-month follow-up, five deaths occurred (31.3%), three from cardiovascular causes (18.75%). Surviving patients showed sustained MR reduction and improved symptoms (89% in NYHA I/II). Ring size analysis suggested a minimum of 36 mm for rigid/semi-rigid rings, while flexible bands allowed successful implantation in sizes as small as 30 mm. CONCLUSIONS: Tendyne V-i-R procedures are technically feasible, effective, and safe in selected high-risk patients with recurrent MR. Ring size thresholds identified may guide patient selection and procedural planning in future interventions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transapical transcatheter mitral valve replacement with apical tethering system. Single-center mid-term results.Interdisciplinary cardiovascular and thoracic surgery · 2026
- Pooled Analysis of Valve-in-Valve and Valve-in-Ring Transcatheter Mitral Valve Replacement Using the SAPIEN Valve.Journal of the American Heart Association · 2026
- Treatment of Failed Mitral Valve Bioprostheses or Repairs: Transcatheter Mitral Valve-in-Valve/Valve-in-Ring Versus Redo Surgical Mitral Valve Replacement.Journal of clinical medicine · 2026
- Mid-Term Clinical Outcomes of Tendyne Transcatheter Mitral Valve Replacement: A Prospective Cohort of 100 Patients with Follow-up to 4 Years.The Journal of thoracic and cardiovascular surgery · 2026
- CT-Based Annular Dimensions in Transcatheter Mitral Valve Replacement: A Multicenter Registry StudyThe Annals of Thoracic Surgery · 2026
- Five-year outcomes of the early-generation Intrepid transapical transcatheter mitral valve replacement systemEuroIntervention · 2026