Fab-targeted gold nanoparticle probes outperform fc-targeted and dual-epitope formats in nanoparticle tracking analysis of a bivalent model analyte: a proof-of-concept study using human IgG
Parvindar M. Sah, Harshala S. Naik, Neeraj Jain, Sahebrao B. Kashid, Aniket K. Gade, Rajesh W. Raut
Key points
From the paper's conclusion- As a methodological proof of concept, we asked whether the epitope that a capture antibody recognises on a multivalent analyte governs the performance of gold nanoparticle (AuNP) aggregation assays read out by nanoparticle tracking analysis (NTA).
Abstract
Introduction Nanoparticle aggregation assays read out by bulk optical measurement are limited in sensitivity because, at low analyte concentrations, only a small fraction of particles associate. As a methodological proof of concept, we asked whether the epitope that a capture antibody recognises on a multivalent analyte governs the performance of gold nanoparticle (AuNP) aggregation assays read out by nanoparticle tracking analysis (NTA). Human immunoglobulin G (IgG) was used purely as a bivalent model scaffold, not as a clinical target. Methods AuNPs were functionalised through a streptavidin bridge with biotinylated antibodies against either the Fab or the Fc region of IgG, and the two probes were tested individually and as a one-to-one mixture across 19.9–199.4 fg/mL (0.13–1.33 fM) of antigen, with association followed by ultraviolet–visible (UV–Vis) spectroscopy and by NTA. Results Both methods ranked the three formats identically. The Fab-targeted probe was the only format with a monotonic, linear response (R 2 = 0.953), giving an NTA limit of detection of 65.1 fg/mL (0.43 fM) within a 35-minute assay, approximately 6.7 × 104-fold below its UV–Vis limit (4.33 ng/mL). Discussion Because the calibrated range spans one order of magnitude and the limit of quantification (197 fg/mL; 1.31 fM) lies at its upper end, the assay is best regarded as detecting and semi-quantitatively ranking antigen rather than quantifying it. The mixed probe gave the largest signal but a stepwise response suited to qualitative screening. The Fc-targeted probe did not titrate; because this preparation was already partially aggregated before antigen addition, its failure cannot be attributed to epitope choice alone. Antibody-free and non-target-antigen controls remained at baseline, but the magnitude of the NTA response exceeds what one-to-one antigen bridging of particles could produce, so the aggregation index is treated as an empirical, antigen-specific indicator whose amplification mechanism remains to be resolved. All measurements were made in dilute buffer, so matrix tolerance was not tested. Validation in serum, comparison with a reference immunoassay, and extension to genuinely low-abundance multivalent biomarkers are required before any diagnostic use is considered.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Antibody Binding to Peptide Conjugated Gold Nanoparticles Preferring Dense Antigen Coating with Small Deflection Angle.ACS nanoscience Au · 2026
- Precision antibody orientation on gold nanoparticles via pH control enables clinic-grade lateral flow detection of acute myocardial infarctionNano Materials Science · 2025
- Overcoming Steric Hindrance for Precise Multiplexed Protein Profiling of Single Extracellular Vesicles.Small methods · 2026
- Tunable Lipid–Corona Interfaces Enable Orientation-Controlled Antibody Immobilization and Enhanced Biofunctionality on Gold NanoparticlesACS Applied Nano Materials · 2026
- Fc Profiling of Polyclonal IgG, IgA and IgM by Light Chain Capturing Coupled with NanoRP-LC-MSJACS Au · 2025
- Bulk LSPR sensitivity and biomolecular response across immobilized nanoparticle-biointerface architectures.Colloids and surfaces. B, Biointerfaces · 2026