Department of Molecular Biology and Genetics, Istanbul Technical University, Istanbul, 34469, Türkiye; Dr. Orhan Öcalgiray Molecular Biology, Biotechnology and Genetics Research Center (MOBGAM), Istanbul Technical University, Istanbul, 34469, Türkiye; Department of Biomedical Engineering, Yildiz Technical University, Istanbul, 34349, Türkiye. · Department of Biomedical Engineering, Yildiz Technical University, Istanbul, 34349, Türkiye.

Key points

From the paper's conclusion
  • The data distinguish pre-biofunctionalization optical response from interface construction and analytical discrimination.

Abstract

Bulk refractive-index sensitivity is widely used to characterize localized surface plasmon resonance (LSPR) sensors, but the response of a finite biomolecular interface also depends on how that optical response is realized after surface construction. We examined this relationship across independently generated, microplate-reader-compatible immobilized gold nanoparticle (AuNP) and gold nanourchin (AuNU) architectures spanning direct-IgG coupling, Protein A/anti-glial fibrillary acidic protein (GFAP) IgG, and anti-receptor-binding domain (RBD) nanobody (Nb) workflows. Selected nanobody branches were further evaluated using receptor-omitted RBD controls and leptin challenge, and the 100 nm AuNU/Nb branch was tested in 10% pooled human serum. A fixed, non-fitted sensing-envelope calculation based on assigned parameters provided a distance-based optical reference. Bulk sensitivities spanned 57-241 nm RIU-1, with the largest value for the 100 nm AuNU ensemble. Downstream responses, however, depended on architecture and interface state. Linker loading did not consistently yield a resolvable receptor-associated step, and the 30 and 60 nm AuNP Protein A/anti-GFAP branches showed compressed GFAP-associated profiles. Anti-RBD nanobody branches produced concentration-dependent buffer responses; on the 100 nm AuNU/Nb branch, receptor-omitted RBD background remained low but non-zero and did not reproduce the larger middle-to-upper-range target response. Leptin also produced a measurable response, while the exploratory 10% serum experiment yielded small, partly non-monotonic serum-centered increments (0.12-0.28 nm). The data distinguish pre-biofunctionalization optical response from interface construction and analytical discrimination. The sensing-envelope calculations provide a conditional geometric reference for interpreting these observations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Bulk LSPR sensitivity and biomolecular response across immobilized nanoparticle-biointerface architectures — Science Skim