Rapid identification of microbial pathogens in intra-abdominal infections using multiplex PCR.
Johanna Bückner, Uwe Groß, Nils Kunze-Szikszay, Michael Ghadimi, Konrad Meissner, Onnen Moerer, Thorsten Perl
Department of General, Visceral, and Pediatric Surgery, University Medical Center Göttingen, Göttingen, Germany. · Institute for Medical Microbiology and Virology, University Medical Center Göttingen, Göttingen, Germany.
Key points
From the paper's conclusion- In conclusion, multiplex PCR cannot replace conventional culture, but may serve as a complementary tool, providing rapid detection of selected pathogens, including anaerobes.
Abstract
Intra-abdominal infections (IAI) resulting from the perforation of hollow viscera are associated with high morbidity and mortality. In addition to timely surgical source control, rapid and accurate pathogen identification is crucial to guide targeted antimicrobial therapy, particularly in polymicrobial infections involving potentially virulent pathogens. In this prospective study (ClinicalTrials.gov NCT07562204), we compared real-time multiplex PCR Unyvero A50 (Curetis®) as a point-of-care (POC) tool with conventional microbiological culture (cMB). 50 patients with suspected hollow organ perforation or peritonitis were included. 2 intraoperative samples were collected per patient: one for immediate PCR testing and one for standard culture-based diagnostics. Turnaround times, pathogen detection rates, resistance marker detections and microbial distribution according to anatomical sampling site were assessed descriptively. PCR results were available on the same day or the next day in all cases (n=41), whereas cMB results required ≥2 days in all cases (n=50). 9 samples (18%) yielded invalid PCR results according to the manufacturer's system output and were excluded from concordance analyses. Among the 41 evaluable sample pairs, complete concordance between PCR and cMB was observed in 29% (12/41), while non-concordant results occurred in 71% (29/41). PCR detected at least one additional pathogen not identified by cMB in 49% (20/41) of cases. Pathogen detection rates and pathogen group distributions were analyzed per protocol in samples with valid PCR results (n=41) and compared with cMB results from the total cohort (n=50). Gram-positive bacteria were detected in 58% (29/50) of cMB and 56% (23/41) of PCR samples. Aerobic/facultative Gram-negative bacteria were detected in 46% (23/50) of cMB samples and in 59% (24/41) of PCR samples. Enterobacteriaceae represented the predominant subgroup and were detected in 34% (17/50) of cMB and 37% (15/41) of PCR samples. Anaerobic bacteria were detected more frequently by PCR than by cMB (cMB 24%, 12/50 vs. PCR 44%, 18/41). In conclusion, multiplex PCR cannot replace conventional culture, but may serve as a complementary tool, providing rapid detection of selected pathogens, including anaerobes. Its implementation may support earlier antimicrobial decision-making in IAIs. Further multicenter studies are needed to evaluate its clinical utility in routine diagnostic workflows.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical evaluation of multiplex pathogen real-time PCR for early detection of pathogens and antimicrobial resistance genes in intra-abdominal infections.World journal of microbiology & biotechnology · 2026
- Diagnostic Stewardship in ICU Pneumonia: Optimizing the Use of Multiplex PCR Panels Through Pre-Analytical Microscopic Screening of Endotracheal AspiratesDiagnostics · 2026
- Multicentre Evaluation of Cepheid Xpert® Research-Use-Only Panel for Molecular Rapid Detection of Gastrointestinal Pathogens.Microorganisms · 2026
- Evaluation of a Direct-from-Blood Molecular Diagnostic Platform for Pathogen Detection in Critically Ill Patients: A Prospective Observational Cohort Study.Open forum infectious diseases · 2026
- Diagnostic Performance of the FilmArray BCID2 Multiplex PCR Panel Applied to Excised Heart Valve Specimens from Patients with Infective Endocarditis.Microorganisms · 2026
- Usage of Multiplex Polymerase Chain Reaction (PCR) Panels at a Single Tertiary Hospital in Manila: Most Common Pathogens Detected and Implications on Antimicrobial Therapy.Acta medica Philippina · 2026