Diagnostic Performance of the FilmArray BCID2 Multiplex PCR Panel Applied to Excised Heart Valve Specimens from Patients with Infective Endocarditis.
Agata Bilewska, Joanna Skrzeczyńska, Monika Dorota, Anna Skowrońska, Elwira Wojtyniak, Katarzyna Darmofalska, Agnieszka Woźniak, Kamil Borek,
Department of Cardiac Surgery, Medicover Hospital, 02-972 Warsaw, Poland. · Department of Clinical Microbiology, Maria Skłodowska-Curie National Research Institute of Oncology, 02-781 Warsaw, Poland.
Key points
From the paper's conclusion- This study evaluated the diagnostic performance of the FilmArray Blood Culture Identification 2 (BCID2) multiplex polymerase chain reaction (PCR) panel applied off-label to excised heart valve specimens.
Abstract
Infective endocarditis (IE) is a life-threatening disease in which rapid identification of the causative pathogen is essential for appropriate antimicrobial therapy. Although blood cultures remain the standard microbiological method, complementary molecular techniques have the potential to improve pathogen detection in selected clinical settings. This study evaluated the diagnostic performance of the FilmArray Blood Culture Identification 2 (BCID2) multiplex polymerase chain reaction (PCR) panel applied off-label to excised heart valve specimens. Excised heart valve specimens obtained from 47 patients undergoing surgery for IE were analysed using the BCID2 panel. The BCID2 results were compared with blood and valve culture results. Forty-two patients were included for blood cultures and 46 for valve cultures. Using blood culture as the clinical reference method, the BCID2 assay demonstrated a sensitivity of 78.4% (95% confidence interval (CI): 61.8-90.2%), a specificity of 60.0% (95% CI: 14.7-94.7%), a positive predictive value (PPV) of 93.5% (95% CI: 78.6-99.2%), and a negative predictive value (NPV) of 27.3% (95% CI: 6.0-61.0%). Agreement between the BCID2 assay and blood culture was low (Cohen's κ = 0.253; 95% CI: -0.068-0.573; p = 0.067). In the secondary comparison using conventional valve culture, sensitivity was 8.8% (95% CI: 1.9-23.7%), whereas specificity was 100% (95% CI: 75.3-100%). These findings suggest that off-label application of the BCID2 panel to excised heart valve specimens may complement conventional microbiological methods in selected patients with infective endocarditis. However, a negative BCID2 result should not be used to exclude infective endocarditis, and larger multicentre studies are warranted to further evaluate the clinical utility of this approach.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic Yield and Incremental Value of 16S rRNA Gene PCR and Sequencing on Excised Heart-Valve Tissue in Infective Endocarditis: A Systematic Review and Meta-Analysis.Diagnostics (Basel, Switzerland) · 2026
- Implementation of a Multimodal Diagnostic Algorithm for Blood Culture-Negative Infective Endocarditis at the Argentine National Reference Laboratory: A Prospective StudymedRxiv · 2026
- Contemporary diagnostic strategies for blood culture-negative infective endocarditis: from conventional microbiology to emerging molecular and multimodality approaches.Infection · 2026
- Analytical and Clinical Evaluation of a Fully Automated Direct-from-Whole-Blood Multiplex PCR Assay Using Large-Volume Reverse Elution for Rapid Bloodstream Infection Diagnosis.Antibiotics (Basel, Switzerland) · 2026
- Evaluation of BioFire® FilmArray® and GENECUBE® for Rapid Molecular Diagnosis of Periprosthetic Hip Joint Infection Using Implant Sonication FluidJournal of Orthopaedic Research · 2026
- Diagnostic Stewardship in ICU Pneumonia: Optimizing the Use of Multiplex PCR Panels Through Pre-Analytical Microscopic Screening of Endotracheal AspiratesDiagnostics · 2026