Material-dependent viscoelastic performance of TPU and PEBA gyroid intervertebral disc replacements under quasi-static and cyclic compression.
Sunil Shetty, Illia Artamonov, Leandro Hippel, Jan Mussler, Hagen Schmal, Michael Seidenstuecker
G.E.R.N. Center for Tissue Replacement, Regeneration & Neogenesis, Department of Orthopedics and Trauma Surgery, Medical Center-Albert-Ludwigs-University of Freiburg, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany. · Department of Orthopedics and Trauma Surgery, Medical Center-Albert-Ludwigs-University of Freiburg, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany.
Key points
From the paper's conclusion- This study compared single-material Gyroid structures with the same nominal anatomically derived L4/L5 geometry using a harmonized secondary analysis of original specimen-level datasets.
Abstract
Thermoplastic polyurethane (TPU) and polyether block amide (PEBA) offer different mechanical profiles for additively manufactured intervertebral disc replacements. This study compared single-material Gyroid structures with the same nominal anatomically derived L4/L5 geometry using a harmonized secondary analysis of original specimen-level datasets. Geometry #08 comprised a 6 mm unit-cell size and a nominal wall thickness of 0.75 mm without a peripheral wall. FlexHard and FlexMed TPU and Spectrum and SainSmart PEBA were investigated. Three additional unloaded reference specimens per material underwent dimensional, gravimetric, and microscopic characterization. FlexHard, FlexMed, and Spectrum met the predefined quasi-static screening criterion of 4000-8000 N at 50% compression, whereas SainSmart remained below 4000 N and was not dynamically tested. Eligible groups completed 700,000 compression cycles between 600 and 2000 N at 5 Hz without apparent mechanical failure (n = 3 per material). Outcomes were evaluated over the final 600,000 cycles following 100,000 conditioning cycles. Structural stiffness increased by 16.1% for FlexHard and 76.5% for FlexMed but decreased by 10.6% for Spectrum. Apparent storage modulus increased by 30.9% and 44.1% in the TPU groups and decreased by 10.3% in Spectrum. Mean loss modulus increased in both TPU groups and decreased in Spectrum, although within-material changes were not significant after multiplicity adjustment. Tan δ and specific damping capacity decreased in all three groups, with both TPU formulations maintaining higher mean damping capacities than Spectrum. Immediately after loading, TPU specimens retained approximately 90% of their initial height, compared with approximately 95% for Spectrum; all groups recovered to approximately 97%-99% after 24 h. These exploratory findings identify complementary profiles in load support, energy dissipation, cyclic adaptation, and recovery. Because manufacturing conditions differed between source datasets, the results characterize the investigated material-manufacturing combinations and support joint optimization of formulation, processing, and architecture.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bioinspired functionally graded TPU gyroid structures for intervertebral disc replacement fabricated by multimaterial 3D printing.Biomedical materials (Bristol, England) · 2026
- Evaluation of 3D-Printed Thermoplastic Polyurethane Nerve Guidance Conduits.Polymers · 2026
- Simulation-Driven Optimization of Nanocomposite Auxetic Intervertebral Disc Substitutes Mimicking Native Mechanics.ACS applied bio materials · 2026
- Additive Manufacturing of Gradient Stiffness Honeycombs Using Thermoplastic Polyurethane Composite Material VariationsAdvanced Engineering Materials · 2025
- Investigating the potential of auxetic structures in tibial insert toward multi-range load-carrying knee implant.The International journal, advanced manufacturing technology · 2026
- Investigation on Mechanical Properties of Functional Graded Hybrid TPMS Structures Inspired Bone ScaffoldsPolymers · 2026