The International journal, advanced manufacturing technology

Investigating the potential of auxetic structures in tibial insert toward multi-range load-carrying knee implant.

Ahmed ElZefzafy, Abdul Wasy Zia

Institute of Mechanical, Process and Energy Engineering (IMPEE), School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, EH14 4AS UK.

Key points

From the paper's conclusion
  • In addition, it is perceived that the auxetic structures-based tibial insert provides tunable effective stiffness, demonstrating the significance of auxetic lattice design and their suitability for a wider range of body weights to ensure mechanical stability, medical safety, and implant longevity.

Abstract

The artificial tibial insert degrades within the human body over service time as a metallic femoral surface continues articulating against it. The degradation rate depends on gait patterns and mainly on the human body weight, as tibial inserts normally lack subject-specific customisation. This article investigates the feasibility of gyroid, square anti-chiral, and triangular auxetic structures for tibial insert applications. The mechanical performance of new tibial designs is compared against a conventional (bulk) tibial insert through computational and experimental studies. The preliminary stress-strain and deformation behaviours are studied with ANSYS Workbench. Whereas the Instron machine is used for experimental studies to test the 3D printed conventional and auxetic structure-based tibial inserts designed in this work. The experimental studies are performed under a wide range of quasi-static and cyclic loading conditions to understand their mechanistic performance and suitability for knee joint functionality. Among gyroid, square anti-chiral and triangular auxetic structures, the triangular design has demonstrated exceptional load-bearing capabilities up to 20 kN, an adequate deflection up to 2.3 mm, along with 34.8% reduction in component weight. The enhanced elastic recovery supported by auxetic structures can provide knee safety under impact loads. In addition, it is perceived that the auxetic structures-based tibial insert provides tunable effective stiffness, demonstrating the significance of auxetic lattice design and their suitability for a wider range of body weights to ensure mechanical stability, medical safety, and implant longevity.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers