Investigating the potential of auxetic structures in tibial insert toward multi-range load-carrying knee implant.
Ahmed ElZefzafy, Abdul Wasy Zia
Institute of Mechanical, Process and Energy Engineering (IMPEE), School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, EH14 4AS UK.
Key points
From the paper's conclusion- In addition, it is perceived that the auxetic structures-based tibial insert provides tunable effective stiffness, demonstrating the significance of auxetic lattice design and their suitability for a wider range of body weights to ensure mechanical stability, medical safety, and implant longevity.
Abstract
The artificial tibial insert degrades within the human body over service time as a metallic femoral surface continues articulating against it. The degradation rate depends on gait patterns and mainly on the human body weight, as tibial inserts normally lack subject-specific customisation. This article investigates the feasibility of gyroid, square anti-chiral, and triangular auxetic structures for tibial insert applications. The mechanical performance of new tibial designs is compared against a conventional (bulk) tibial insert through computational and experimental studies. The preliminary stress-strain and deformation behaviours are studied with ANSYS Workbench. Whereas the Instron machine is used for experimental studies to test the 3D printed conventional and auxetic structure-based tibial inserts designed in this work. The experimental studies are performed under a wide range of quasi-static and cyclic loading conditions to understand their mechanistic performance and suitability for knee joint functionality. Among gyroid, square anti-chiral and triangular auxetic structures, the triangular design has demonstrated exceptional load-bearing capabilities up to 20 kN, an adequate deflection up to 2.3 mm, along with 34.8% reduction in component weight. The enhanced elastic recovery supported by auxetic structures can provide knee safety under impact loads. In addition, it is perceived that the auxetic structures-based tibial insert provides tunable effective stiffness, demonstrating the significance of auxetic lattice design and their suitability for a wider range of body weights to ensure mechanical stability, medical safety, and implant longevity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Simulation-Driven Optimization of Nanocomposite Auxetic Intervertebral Disc Substitutes Mimicking Native Mechanics.ACS applied bio materials · 2026
- Bioinspired auxetic metamaterial liners and sockets for transtibial prostheses: Energy absorption and stress redistributionJournal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · 2025
- Topology-optimised auxetic tibial implants: A finite element study toward reducing aseptic loosening.Computers in biology and medicine · 2026
- A auxetic metamaterial structure: analysis of shear and bending, mechanical characterization4D Printing · 2026
- Bioinspired functionally graded TPU gyroid structures for intervertebral disc replacement fabricated by multimaterial 3D printing.Biomedical materials (Bristol, England) · 2026
- Auxetic structures for energy absorption: A review on design, manufacturing, optimization, and applicationsJournal of Intelligent Material Systems and Structures · 2025