AI-Enhanced finite element analysis for optimal material selection in total knee replacement.
Iman Shakir Tawfeeq, Taha A Elwi
College of ElectroMechanical Engineering, University of Technology, Baghdad, Iraq. · Department of Automation and Artificial Intelligence Engineering, College of Information Engineering at Al-Nahrain University, Baghdad, Iraq.
Key points
From the paper's conclusion- Multi-criteria decision-making using TOPSIS ranked Co-Cr as the optimal material under stress-prioritized weighting (0.6/0.4); though, sensitivity analysis revealed that Stainless Steel converts optimal when displacement/compliance is prioritized (0.4/0.6).
Abstract
The increasing prevalence of total knee replacement (TKR) surgery and its association with aseptic loosening present a significant research challenge. This issue can be mitigated by selecting optimal materials for TKR components. This paper presents a hybrid approach combining Finite Element Method (FEM) with Artificial Intelligence (AI) techniques for optimal material selection in TKR. Simulations of four normal movements-compression, distraction, medial bending, and lateral bending-were performed on a 3D model of the artificial knee. Four materials were evaluated: Cobalt-Chromium (Co-Cr), Zirconium (Zr), Stainless Steel, and Titanium (Ti). To simulate ligamentous constraints during distraction loading, a model of a nonlinear spring element was included, furnishing more physiologically realistic boundary conditions. An Artificial Neural Network (ANN) was trained on FEM simulation data to predict material performance with 98.7% accuracy for stress prediction (R2 = 0.987), while displacement prediction achieved R2 = 0.985. Multi-criteria decision-making using TOPSIS ranked Co-Cr as the optimal material under stress-prioritized weighting (0.6/0.4); though, sensitivity analysis revealed that Stainless Steel converts optimal when displacement/compliance is prioritized (0.4/0.6). Under axial compression of 1300 N, maximum stress for Co-Cr and Zr was 4.207 × 108N/m2 and 3.921 × 108N/m2, respectively. Under distraction: 4.321 × 108N/m2 and 4.142 × 108N/m2. Under medial bending: 1.101 × 108N/m2 and 1.088 × 108N/m2. Under lateral bending: 1.119 × 108N/m2 and 1.102 × 108N/m2. The AI-based approach reduced computational time by 73% compared to full FEM simulations while maintaining high prediction accuracy. This time-saving shows the promise of the surrogate model for large scale materials screening and patient specific implant optimization, but further biocompatibility and tribological validation will be required for clinical translation of these findings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Asymmetric Metaphyseal Cones for AORI Type 2 Medial Defects in Tibial Plateau Fractures during Acute TKAJournal of Orthopaedic Research® · 2026
- Artificial Intelligence-Based Three-Dimensional Preoperative Planning for Total Knee Arthroplasty in End-Stage Knee Osteoarthritis.Journal of visualized experiments : JoVE · 2026
- Computational analysis of L4–L5 interspinous process devices and interbody fusion spacers using ceramic and polymeric materials via finite element modeling and artificial intelligenceScientific Reports · 2025
- Native varus angle does not affect the primary fixation of cementless TKA using kinematic alignment - A population-based FE study.Journal of biomechanics · 2026
- Assessing the Clinical Utility of Finite Element Analysis Using Post-operative CT-Derived Models: A Material Comparison of Multi-level Spinal Fusion ConstructsbioRxiv · 2026
- Toward foundation-model-assisted biomechanical simulation of the knee joint: Current evidence, limitations, and future directions.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026