Frontiers in bioengineering and biotechnology

Toward in vivo assessment of skin mechanical properties for flap design: challenges, methods, and technical pathways.

Hui Shen, Amelia Palacios, Sofia Deek, Tomas C Hastings, Aarna Veera, Andy Wu, Guang Yang, Xiangyi Cheng

Dr. Carl D. Clay and H. Jane Clay Department of Mechanical Engineering, The T.J. Smull College of Engineering, Ohio Northern University, Ada, OH, United States. · Department of Electrical and Computer Engineering, Frank R. Seaver College of Science and Engineering, Loyola Marymount University, Los Angeles, CA, United States.

Preclinical

Key points

From the paper's conclusion
  • We therefore conducted a comprehensive narrative review of the literature published from 1969 to the present on in vivo skin mechanical property measurement.

Abstract

There is a strong need to quantify skin mechanical properties for flap design in plastic surgery, such as syndactyly reconstruction. Quantitative measurement of skin mechanical properties enables more accurate surgical planning, thereby improving surgical outcomes and reducing complications. Although a large number of methods and devices have been proposed, nearly none of them have been applied in surgical practice. We therefore conducted a comprehensive narrative review of the literature published from 1969 to the present on in vivo skin mechanical property measurement. To identify the factors limiting clinical application, studies using suction, indentation, torsion, stretching, non-contact, and computational approaches were screened and categorized based on their underlying mechanical assumptions and boundary conditions. Three fundamental paradoxes limiting clinical translation were identified: (1) conventional engineering characterization requires destructive testing, which is incompatible with preserving intact skin for surgery; (2) in vivo measurements inevitably capture surrounding tissue boundary constraints rather than intrinsic skin mechanics; and (3) engineering analyses depend on stress-based parameters and skin thickness, whereas thickness is rarely considered in clinical flap planning. Furthermore, inverse numerical models, such as finite element analysis, rely on idealized assumptions that may not fully reflect complex, patient-specific surgical conditions. Rather than attempting to identify a universally accurate conventional measurement device, this review proposes a novel paradigm shift: combining non-invasive microstructural imaging with computer vision and machine learning to predict mechanical transition thresholds (e.g., collagen alignment and tangent modulus) directly from unstretched tissue, with the goal of enabling patient-specific, computational surgical flap planning.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers