A Synthetic Digital Anatomy Approach to Determine the Effects of Tissue Composition and Alignment on Transfemoral Residual Limb Mechanics.
Marissa A Pirritano, Joshua D Childress, Jason M Souza, Nicholas P Fey
Key points
From the paper's conclusion- We constructed multi-material synthetic residual limb models with varying tissue compositions and mechanically tested them under cyclical axial compression.
Abstract
The soft tissue envelope within the residual limb influences prosthetic fit, function, and user comfort. The purpose of this study was to examine the influence of residual limb tissue composition and skeletal alignment on its mechanical properties during axial loading. We hypothesized that deviations in the adipose and muscle volume of the limb, as well as frontal plane alignment, will alter the mechanical stiffness and energy loss. We constructed multi-material synthetic residual limb models with varying tissue compositions and mechanically tested them under cyclical axial compression. Stiffness was quantified as the change in force divided by the change in displacement over the entire loading response, and energy loss was quantified as the mechanical hysteresis of the force-displacement loop. A large (~35%) reduction in soft tissue volume, representative of the change from pre- to post-limb recontouring surgery, resulted in an increase in stiffness of 57.6% out-of-socket and 17.3% in-socket relative to the pre-surgery model. Small (±2.5%) changes in tissue composition produced up to an 18.6% change in stiffness and up to a 59.2% change in hysteresis relative to the nominal post-surgery model. Finally, alignment in the frontal plane (±4° and ±8°) had significant effects on stiffness and hysteresis both pre- and post-surgery. We expect that clinical and technical approaches that optimize these factors could potentially contribute to improvements in whole-body outcomes such as metabolic cost and user comfort. In addition, these testing and verification methods offer a non-invasive and powerful technique to test patient-specific residual limb properties.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of the pelvic bone and gluteal zone over the stress state at the interaction between the prosthetic socket and residual limb for people with transfemoral amputation.Frontiers in bioengineering and biotechnology · 2026
- Mechanical evaluation of 3D-printed above-knee prosthetic sockets using a biofidelic hyperelastic silicone limb surrogate.Medical engineering & physics · 2026
- Bioinspired auxetic metamaterial liners and sockets for transtibial prostheses: Energy absorption and stress redistributionJournal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · 2025
- An evaluated gait-driven finite element framework for transfemoral limb–socket interface biomechanics and socket design evaluationJournal of NeuroEngineering and Rehabilitation · 2026
- Evaluation of Below‐Knee Prosthetic Socket Mechanical Characteristics via Experimental and Numerical MethodsAdvances in Polymer Technology · 2026
- The effect of prosthetic alignment and multiplanar deformation of a single prosthetic foot on musculoskeletal model predictions in unilateral transtibial prosthesis users.Journal of biomechanics · 2026