Plantar-pressure-guided support-plate position control for a walker-assisted lower-limb rehabilitation exoskeleton.
Yuhui Yang, Wenyu Zhao, Yuanxiang Guo, Zhijue Huang, Xueshan Gao, Xin Han, Junlin Deng
College of Mechanical and Marine Engineering, Beibu Gulf University, Qinzhou, China. · School of Automation, Guangxi University of Science and Technology, Liuzhou, China.
Key points
From the paper's conclusion- This study proposes a multi-zone plantar-pressure-guided position control method for the support-force adjustment plate of a walker-assisted lower-limb exoskeleton.
Abstract
INTRODUCTION: Maintaining appropriate foot-ground contact is important for walker-assisted lower-limb exoskeleton training. Excessive plantar loading may increase initial-contact impact and actuator load, whereas excessive unloading may reduce frictional contact and contact stability. Passive spring support can provide impact buffering, but it cannot adjust the support working point according to gait phase or plantar-pressure feedback. METHODS: This study proposes a multi-zone plantar-pressure-guided position control method for the support-force adjustment plate of a walker-assisted lower-limb exoskeleton. The system combines a fixed-stiffness spring with a vertical screw-driven adjustment plate. Total plantar pressure was obtained by fusing signals from 18 pressure cells on each instrumented foot and served as the main feedback variable. Regional plantar pressures and the center of pressure supported gait-phase recognition and contact-state estimation. A phase-related plantar-pressure target band was used as an engineering constraint to maintain stable foot-ground contact. Experiments involved three healthy male participants under no-spring, passive-spring, and proposed-control conditions during low-speed frame-assisted walking. RESULTS AND DISCUSSION: In the proposed-control condition, peak total plantar pressure was 0.687 ± 0.015 BW, 21.2% lower than in the no-spring condition and 6.7% lower than in the passive-spring condition. Relative to the no-spring condition, the loading rate decreased from 9.02 ± 0.53 to 2.56 ± 0.07 BW/s, and the initial-contact impact impulse decreased from 0.143 ± 0.009 to 0.064 ± 0.002 BW ⋅ s. Hip-knee actuator electrical energy decreased from 38.95 ± 2.20 to 27.24 ± 1.54 J/gait cycle. After vertical-axis actuator energy was included, measured total actuator electrical energy was 30.60 ± 1.68 J/gait cycle and remained lower than in both comparison conditions. These preliminary results suggest that plantar-pressure feedback can regulate support-plate position, attenuate contact impact, and reduce measured robotic actuator effort during low-speed walker-assisted walking.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From pressure to force: a device-independent, predictive model of plantar loading for personalized orthoses.Frontiers in bioengineering and biotechnology · 2026
- Spatial Decoupling of Foot-Substrate Cross-Talk in Plantar Pressure Sensor Arrays.Biomimetics (Basel, Switzerland) · 2026
- Next-generation control strategies for lower-extremity exoskeletons: State-of-the-art, limitations, and future directions.PM & R : the journal of injury, function, and rehabilitation · 2026
- Effect of a robotic insole-type active assist device on horizontal ground reaction force and center-of-pressure stability during stepping in patients with medial knee osteoarthritis.Frontiers in robotics and AI · 2026
- Ground Reaction Force-Aware Model Predictive Control for Underactuated Upright Physical AssistancearXiv · 2026
- Dual-loop control of lower-limb exoskeletons using adaptive admittance and nonlinear extended state observer-based active disturbance rejectionRobotica · 2026