Non-Newtonian blood rheology significantly alters hemodynamic predictions during cardiac looping: a computational study.
Matthew C Watson, Erica C Kemmerling, Lauren D Black
Department of Biomedical Engineering, Tufts University, Medford, MA, United States. · Department of Mechanical Engineering, Tufts University, Medford, MA, United States.
Key points
From the paper's conclusion- These findings demonstrate that non-Newtonian rheology can substantially alter predicted hemodynamic quantities during cardiac looping and should therefore be considered in future developmental hemodynamic models, particularly when wall shear stress and pressure magnitudes are used to infer mechanobiological responses.
Abstract
INTRODUCTION: Hemodynamic forces play a key role in early cardiac morphogenesis, yet many computational studies assume Newtonian blood behavior. Here, we evaluate the impact of non-Newtonian shear-thinning rheology on flow patterns, pressure distributions, and wall shear stress (WSS) during cardiac looping using idealized three-dimensional models of the embryonic heart tube. METHODS: Five geometries representing progressive looping stages, from a linear tube to an S-shaped configuration with ventricular ballooning, were analyzed under pulsatile flow using both Newtonian and power-law viscosity models. RESULTS AND DISCUSSION: Across all stages, Reynolds numbers (Re ≈ 1-7) and Womersley numbers (Wo ≈ 0.3) indicated laminar, quasi-steady flow consistent with embryonic conditions. Incorporating shear-thinning rheology produced substantial deviations from Newtonian predictions, with peak systolic WSS differing by up to ∼94% (range 64%-94% depending on stage) and pressure drops by up to ∼70% (range 48%-70% depending on stage). These effects were most pronounced in regions of increased curvature and geometric complexity. These findings demonstrate that non-Newtonian rheology can substantially alter predicted hemodynamic quantities during cardiac looping and should therefore be considered in future developmental hemodynamic models, particularly when wall shear stress and pressure magnitudes are used to infer mechanobiological responses.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Organ-scale pulsatile blood flow reconstruction in the avian yolk sac embryoarXiv · 2026
- Multifactorial assessment of hemodynamic thresholds in a three-layered elastic stenosed coronary arteryPhysics of Fluids · 2026
- Geometry-Dependent Variability in Rotational Rheometry of Whole Blood: Implications for Flow Curve Measurement and Protocol Standardization.Methods and protocols · 2026
- Three-Dimensional Fluid-Structure Interaction Reveals Trade-offs Among Oxygen Delivery, Shear, and Washout in Pediatric Roller-Pump Cardiopulmonary Bypass.bioRxiv : the preprint server for biology · 2026
- Numerical simulation of electroosmotic blood flow through progressive stenotic artery with a catheter under the joule heating and magnetic field effects.Computers in biology and medicine · 2026
- Geometry-Dependent Wall Shear Stress in Standardized 50% Coronary Stenoses: Effects of Pressure and Hematocrit in a Parametric CFD StudyMathematical and Computational Applications · 2026