Focused ultrasound increases Lucifer Yellow transport across hCMEC/D3 endothelial monolayers
Sam Bleker, Kyra‐Elisa Maria Redeker, Gerrit Meußler, Ralf Brinkmann, Jürgen Brockmöller, Christoph Rußmann
University of Applied Sciences and Arts Hildesheim/Holzminden/Göttingen · Universitätsmedizin Göttingen
Key points
From the paper's conclusion- Together, these results provide a controlled in vitro framework for temporally resolving FUS-associated transport in this monolayer–insert system.
Abstract
Introduction Focused ultrasound (FUS) is being investigated as a non-invasive approach to modulate vascular barriers and thereby facilitate drug delivery to the central nervous system and other protected tissues. However, interpretation of in vitro endothelial responses to FUS is complicated by culture-vessel acoustics and by the need to distinguish transport occurring during exposure from transport occurring afterward. Methods We investigated Lucifer Yellow transport across hCMEC/D3 human cerebral microvascular endothelial monolayers cultured on ThinCert inserts during and after a 60-s continuous-wave FUS exposure at 1.2 MHz and 80 V pp (peak-to-peak voltage) without added microbubbles. Hydrophone measurements at 100 V pp identified 1.2 MHz as the frequency yielding the highest mean peak rarefactional pressure in the frequency scan at an axial distance of 5.0 mm from the lens apex. Separate axial scans at 1.2 MHz located the axial pressure maximum at the same distance; first-order voltage scaling of the corresponding peak rarefactional focal pressure (PRFP) yielded an estimated PRFP of 0.838 ± 0.054 MPa for the 80-V pp condition in the calibration geometry. Lucifer Yellow accumulation was quantified immediately before exposure, at the end of exposure, and 9 min later in eight independent paired experiments using sampling- and volume-corrected receiver amounts. Results During the 60-s exposure interval, the mean control-adjusted increase was 0.283 nmol (95% confidence interval, 0.185–0.380 nmol; Holm-adjusted P = 0.000475 ; Cohen’s d z = 2.43 ), and all eight experiments showed the same effect direction. During the subsequent 9-min interval, the additional control-adjusted accumulation was 0.035 nmol (95% confidence interval, −0.100–0.171 nmol; Holm-adjusted P = 0.555 ). In a separate preliminary cell-free session, three within-session FUS/control pairs did not reproduce the positive exposure-interval response seen in the cellular series; these observations were descriptive only. In five separate paired experiments, acute Calcein-AM- and ethidium homodimer-1-derived image metrics showed mixed FUS-minus-control differences without a reproducible FUS-associated direction. Discussion These findings demonstrate an exposure-associated increase in Lucifer Yellow transport across the hCMEC/D3 monolayer–insert system that arose predominantly during insonification, without statistically detectable continued differential accumulation during the observed post-exposure interval. Together, these results provide a controlled in vitro framework for temporally resolving FUS-associated transport in this monolayer–insert system.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Safe focused ultrasound-mediated blood-brain barrier opening is driven primarily by transient reorganization of tight junctionsCommunications Engineering · 2026
- Microbubble Timing and Vascular Geometry Are Associated With Vessel-Level Blood-Brain Barrier Opening During Focused Ultrasound.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2026
- Transcranial microbubble-enhanced ultrafast Doppler imaging of ultrasound-induced brain stimulation using a dual-mode concave low-frequency array transducer.Ultrasonics · 2026
- In vitro targeted microbubble adhesion exhibits a maximum at intermediate acoustic pressuresFrontiers in Acoustics · 2026
- A preclinical platform for focused ultrasound delivery from microplate to awake brainbioRxiv · 2026
- Tuning endothelial barrier permeability with ultrasound: a pulse-length-dependent interplay between bubble dynamics and cellular bioeffectsUltrasonics Sonochemistry · 2026