The Canadian journal of urology

Operating room turnover times for radical prostatectomy: a single center retrospective comparison between multimodular and single-boom robotic systems.

Giuseppe Pallotta, Maria Chiara Sighinolfi, Simona Presutti, Antonio Silvestri, Ela Patel, Stefano Terzoni, Stefano Abed, Daniele Fettucciari,

Department of Urology, Fondazione Policlinico Gemelli IRCCS, Rome, Italy. · Medicine Department, Stanford University, Stanford, CA, USA.

Observational

Key points

From the paper's conclusion
  • In a standardized, high-volume setting, the multimodular architecture of the Hugo RAS system does not result in significantly longer OR turnover times compared to the Da Vinci Xi. Institutional factors such as team experience and workflow standardization appear to outweigh platform-specific technical differences in determining OR efficiency.

Abstract

BACKGROUND: The introduction of multimodular robotic platforms has raised concerns regarding operating room (OR) efficiency compared to established single-boom systems. This issue is particularly relevant in high-volume robotic programs, where OR turnover time (ORTT) represents a key determinant of productivity and cost-effectiveness. The aim of this study was to compare OR turnover time and closure-to-incision time between a multimodular robotic system (Hugo™ RAS) and a single-boom system (Da Vinci® Xi) during robot-assisted laparoscopic radical prostatectomy in a standardized, high-volume setting. METHODS: We conducted a single-center retrospective cohort study comparing ORTT and closure-to-incision time (CTIT) between the Da Vinci® Xi and Hugo™ RAS systems in robot-assisted laparoscopic radical prostatectomy (RALP). Only homogeneous OR sessions exclusively dedicated to RALP and performed by a stable, experienced robotic team were included. RESULTS: A total of 84 turnovers were analyzed (32 Da Vinci Xi and 52 Hugo RAS). Baseline patient characteristics were comparable between groups. Median ORTT was 45.5 min for Da Vinci Xi and 49.0 min for Hugo RAS (p = 0.139). Median CTIT was 99.0 and 93.5 min, respectively (p = 0.813). CONCLUSIONS: In a standardized, high-volume setting, the multimodular architecture of the Hugo RAS system does not result in significantly longer OR turnover times compared to the Da Vinci Xi. Institutional factors such as team experience and workflow standardization appear to outweigh platform-specific technical differences in determining OR efficiency.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers