Journal of robotic surgery

Comparison of short-term oncological and functional outcomes between the da Vinci and toumai platforms in robotic radical prostatectomy.

Augusto Buffa, Ignacio Tobia, Pablo Francisco Martinez, Agustin Romeo, Wenceslao Villamil

Urology Department, Hospital Italiano de Buenos Aires, Tte. Gral. Juan Domingo Perón 4190, C1199, Buenos Aires, Argentina. augusto.buffa@hospitalitaliano.org.ar. · Urology Department, Hospital Italiano de Buenos Aires, Tte. Gral. Juan Domingo Perón 4190, C1199, Buenos Aires, Argentina.

Key points

From the paper's conclusion
  • We compared complications, and short-term oncological and functional outcomes between the da Vinci and the new Toumai platforms in RARP.

Abstract

Robot-assisted radical prostatectomy (RARP) is a standard treatment for localized prostate cancer (PCa). As new, lower-cost robotic platforms reach Latin America, comparative evidence remains scarce. We compared complications, and short-term oncological and functional outcomes between the da Vinci and the new Toumai platforms in RARP. Single-center, prospective, non-randomized study of patients older than 40 years with localized PCa undergoing RARP between June 2025 and July 2026. The first 100 consecutive Toumai cases were compared with 100 consecutive da Vinci cases operated during the same period; platform allocation depended on operating-room availability, without matching or randomization. Salvage RARP was excluded. Perioperative variables, Clavien-Dindo complications, pathological outcomes, positive surgical margins (PSM), undetectable PSA (< 0.1 ng/mL) and continence (pads/day) at one and three months were analyzed. Two hundred patients were analyzed (100 Toumai vs. 100 da Vinci) with comparable baseline characteristics. Operative time (215.0 vs. 200.3 min) and console time (193.6 vs. 178.0 min) were longer with Toumai (p = 0.001 and p < 0.001, respectively), while docking time did not differ significantly (21.4 vs. 22.3 min; p = 0.147). Hospital stay (1.6 days; p = 0.819), catheter duration (10.7 vs. 10.8 days; p = 0.671), overall complications (18% vs. 10%; p = 0.103), PSM (19% vs. 17%; p = 0.713) and undetectable PSA (96% vs. 93%; p = 0.352) were similar. Continence (no pads) was 84% vs. 73% at one month (p = 0.058) and 87% vs. 85% at three months (p = 0.314). In a high-volume center, the da Vinci and Toumai platforms showed comparable short-term oncological, functional, and complication outcomes, including similar platform docking times despite longer total operative and console times with Toumai.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers