Accuracy and clinical outcomes of robot-assisted deep brain stimulation lead placement using a floor-mounted robotic navigation system: a prospective multicenter study.
Francisco A Ponce, Arnold Vardiman, Markey Olson, Samantha Franklin, Jayla Hatcher, Samatha Guerra
1Department of Functional Neurosurgery, Barrow Neurological Institute, Phoenix, Arizona; and. · 2Department of Neurological Surgery, Methodist Hospital Stone Oak, San Antonio, Texas.
Key points
From the paper's conclusion- DBS electrode implantation using the new robot-assisted system demonstrated high plan-to-place accuracy comparable or superior to historical frame-based and robotic platforms. The safety profile and operative efficiency, reflected by very low complication rates and similar OT and LOS to published literature, support the system as a viable alternative to standard frame-based stereotaxy.
Abstract
OBJECTIVE: The aim of this study was to evaluate clinical data to assess the accuracy and safety of a new robot system used for deep brain stimulation (DBS) lead placement. METHODS: A prospective, multicenter, single-arm study included 60 patients indicated for DBS. Patients aged 18-85 years with Parkinson's disease, essential tremor, or dystonia were enrolled. The primary outcome was electrode accuracy at the tip, 40 mm from the tip, and the entry point compared with the planned trajectory. Secondary outcomes included operative time (OT), length of stay (LOS), and perioperative complications through discharge. RESULTS: The cohort (mean age 67.1 ± 9.9 years) primarily consisted of patients with Parkinson's disease (n = 46). The mean OT was 159.0 ± 26.7 minutes, and the mean LOS was 1.6 ± 1.5 days. The complication rate and return to the operating room rate were both 0%. The mean tip error was 0.8 ± 0.5 mm, error at 40 mm from the tip was 0.4 ± 0.5 mm, and entry point error was 1.0 ± 0.8 mm. CONCLUSIONS: DBS electrode implantation using the new robot-assisted system demonstrated high plan-to-place accuracy comparable or superior to historical frame-based and robotic platforms. The safety profile and operative efficiency, reflected by very low complication rates and similar OT and LOS to published literature, support the system as a viable alternative to standard frame-based stereotaxy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Three-Dimensional Point-Cloud Learning for Patient-Specific Deep Brain Stimulation Motor Response Prediction in Parkinson Disease.BME frontiers · 2026
- Accuracy and clinical utility of the compact micro-robot: a retrospective study of 95 cases.Frontiers in oncology · 2026
- Robotic Arm Alignment System for Electrode Implantation in Invasive Epilepsy Monitoring: Clinical Experience and Accuracy in a Consecutive Patient Series with Comparison to the Literature.Journal of clinical medicine · 2026
- Clinical Accuracy and Patient Experience Following Robotic-Assisted Full-Arch Implant Rehabilitation: A Case Series.Dentistry journal · 2026
- Can Intraoperative Therapeutic Window Data Predict Chronic Contact Selection in Deep Brain Stimulation?Current Directions in Biomedical Engineering · 2026
- Dual-target VIM-PSA deep brain stimulation using octopolar electrodes: surgical technique and feasibility study.Frontiers in neurology · 2026