Idiopathic Macular Hole Surgery without Intraocular Gas Tamponade: Surgical Technique, Biological Rationale, and Initial Clinical Experience.
Libor Hejsek
Key points
From the paper's conclusion- IMH surgery without gas tamponade represents a promising alternative to standard surgery. With the correct ILM flap technique, it enables us to achieve comparable anatomical and functional results while reducing the burden on the patient. However, further prospective studies are necessary to confirm the effectiveness of this method.
Abstract
AIM: The aim of the study is to describe the technique of idiopathic macular hole (IMH) surgery without the use of intraocular gas tamponade and to present the author's first clinical experience. MATERIAL AND METHODS: The operation is performed using pars plana vitrectomy, with the creation of an inverted internal limiting membrane flap (ILM flap). The flap of the patch is temporarily stabilized with decalin and then with an ocular viscoelastic device, without the subsequent use of gas tamponade (and without face-down positioning). The anatomical and functional outcome was evaluated with the aid of optical coherence tomography (OCT) and best-corrected visual acuity. Two case reports of patients with successful IMH closure using this technique are presented. RESULTS: In all presented cases, anatomical closure of the macular hole was achieved and visual acuity improved. OCT demonstrated a relatively rapid restoration of the foveal architecture. The postoperative course was without complications and the patients were not burdened by the limitations and risks associated with gas tamponade. CONCLUSION: IMH surgery without gas tamponade represents a promising alternative to standard surgery. With the correct ILM flap technique, it enables us to achieve comparable anatomical and functional results while reducing the burden on the patient. However, further prospective studies are necessary to confirm the effectiveness of this method.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Macular Hole Surgery With ILM Flap, Viscoelastic, and Air Tamponade Without Positioning.Retina (Philadelphia, Pa.) · 2026
- Viscoelastic-Assisted Rescue of Unintended Free Internal Limiting Membrane Flaps During Macular Hole Surgery: A Two-Case Report.Journal of clinical medicine · 2026
- Multi-Flap Free Internal Limiting Membrane Grafting with Sub-Perfluorocarbon Liquid Stabilization: A Hybrid Technique for Refractory Macular Holes.Retinal cases & brief reports · 2026
- Anterior Capsular Flap Assisted Re-surgery for Persistent Full-Thickness Macular Hole.Retinal cases & brief reports · 2026
- Temporal inverted internal limiting membrane flap technique versus conventional internal limiting membrane peeling technique for large macular holes: a retrospective comparative study.BMC ophthalmology · 2026
- Long-term consecutive macular hole surgery follow-up study in a large retrospective cohort.Journal francais d'ophtalmologie · 2026