Macular Hole Surgery With ILM Flap, Viscoelastic, and Air Tamponade Without Positioning.
Sevim Ayça Seyyar, Oğuzhan Saygılı, Burçak Balyemez
Gaziantep University School of Medicine, Department of Ophthalmology, Gaziantep, Turkey.
Key points
From the paper's conclusion- The viscoelastic-assisted temporal inverted ILM flap technique achieves successful MH closure using air as the sole tamponade agent, without gas endotamponade or postoperative head positioning, yielding favorable anatomical and functional outcomes with enhanced patient comfort.
Abstract
PURPOSE: To report the results of macular hole (MH) surgery performed using the viscoelastic-supported temporal inverted ILM flap technique with air tamponade alone, without gas endotamponade or postoperative head positioning. METHODS: A temporal ILM flap was created in all patients and inverted over the MH with perfluorocarbon liquid (PFCL). After a fluid-air and PFCL-air exchange, a dispersive viscoelastic agent was injected over the inverted flap under air, covering an area of two-to-three-disc diameters. The sclerotomies were closed with the eye filled entirely with air, without any subsequent gas exchange. No head positioning was advised postoperatively. Data on preoperative MH size, best-corrected visual acuity (BCVA), MH closure rate, closure pattern, and postoperative complications were collected. RESULTS: The study included 78 eyes of 71 patients. MH closure was achieved in all 78 eyes (100%) after a single surgical procedure. U-shaped closure occurred in 82.1%, V-shaped in 14.1%, and W-shaped in 3.8%. Significant BCVA improvement was observed (p<0.001), with no significant change in IOP (p=0.057). CONCLUSION: The viscoelastic-assisted temporal inverted ILM flap technique achieves successful MH closure using air as the sole tamponade agent, without gas endotamponade or postoperative head positioning, yielding favorable anatomical and functional outcomes with enhanced patient comfort.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Idiopathic Macular Hole Surgery without Intraocular Gas Tamponade: Surgical Technique, Biological Rationale, and Initial Clinical Experience.Ceska a slovenska oftalmologie : casopis Ceske oftalmologicke spolecnosti a Slovenske oftalmologicke spolecnosti · 2026
- Viscoelastic-Assisted Rescue of Unintended Free Internal Limiting Membrane Flaps During Macular Hole Surgery: A Two-Case Report.Journal of clinical medicine · 2026
- Temporal inverted internal limiting membrane flap technique versus conventional internal limiting membrane peeling technique for large macular holes: a retrospective comparative study.BMC ophthalmology · 2026
- Subretinal balanced salt solution injection versus the inverted internal limiting membrane flap technique for full-thickness macular holes.International ophthalmology · 2026
- Temporal inverted internal limiting membrane flap technique for a 500 μm full-thickness macular hole: A case report.Medicine · 2026
- Long-term consecutive macular hole surgery follow-up study in a large retrospective cohort.Journal francais d'ophtalmologie · 2026