Patient Communication and Radiation Safety in [177Lu]Lu-PSMA Radiopharmaceutical Therapy: International Survey of 102 Theranostic Centers.
Josef Zahner, Lena M Unterrainer, Johannes Czernin, Jeremie Calais, Matthias Eiber, Wolfgang P Fendler, Rudolf A Werner, Linda Gardner,
Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Munich, Germany. · Department of Nuclear Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany; lena.unterrainer@mri.tum.de.
Key points
From the paper's conclusion- Methods: An international survey was conducted among theranostic centers performing [177Lu]Lu-PSMA RPT.
Abstract
[177Lu]Lu-PSMA radiopharmaceutical therapy (RPT) is increasingly administered worldwide in both inpatient and outpatient settings. Despite its growing use, there is no harmonized international guidance on what patients should be told before, during, and after therapy. This study aimed to capture current clinical practice and expert opinion to identify areas of consensus and divergence to develop a patient information template. Methods: An international survey was conducted among theranostic centers performing [177Lu]Lu-PSMA RPT. The questionnaire covered pretreatment procedures, therapy procedures, radiation precautions guidance, and posttreatment procedures. Inpatient and outpatient settings were evaluated separately. Results: In total, 102 centers from 23 countries participated. High agreement was observed for most pretreatment procedures, core therapy aspects, and general posttreatment guidance. In contrast, substantial variability was identified in posttreatment radiation precautions, particularly regarding distancing measures, duration of precautions, transportation after discharge, household and hygiene recommendations, and guidance affecting social interactions. Conclusion: This international survey demonstrated broad consensus for core clinical procedures but showed variability in posttreatment radiation precautions after RPT. By summarizing current practice and translating it into a patient information template, this project supports more consistent patient guidance across diverse clinical settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Implementing [177Lu]Lu-PSMA-617 radioligand therapy in clinical practice: a multistakeholder evaluation of real-world experience and implementation challenges.EJNMMI reports · 2026
- Radiation safety management for stereotactic body radiation therapy incidentally concurrent with Pluvicto® (Lu-177) therapy - a case report.Journal of applied clinical medical physics · 2026
- Harmonizing calibrations for multi-center 177Lu dosimetry: insights from the Pan-Canadian PR.21 trialEJNMMI Physics · 2026
- Reverse PSMA Theranostic Discordance: Reproducible ¹⁷⁷Lu-PSMA-617 Uptake in Skeletal Metastases Inconspicuous on Serial ¹⁸F-PSMA-1007 PET/CT.Clinical nuclear medicine · 2026
- Closing the loop in PSMA radiopharmaceutical therapy for prostate cancer: from eligibility to decision-validated treatment.Frontiers in medicine · 2026
- An International Study of Factors Affecting Variability of Dosimetry Calculations, Part 6: Lessons Learned, Achievable Variability, and the Road Ahead.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026