Prostate-Specific Membrane Antigen PET/CT Segmentation Guided by Vision Language Models Embedding Clinical Report Semantics.
Mahan Pouromidi, Nourhan Bayasi, Rezvan Samimi, Elinaz Hosseinzadeh, Ghasemali Divband, Babak Nickkholgh, Zohreh Adinehpour, Shaghayegh Shafiee Dastgerdi,
Department of Basic and Translational Research, BC Cancer Research Institute, Vancouver, British Columbia, Canada. · Department of Medical Radiation Engineering, Shahid Beheshti University, Tehran, Iran.
Key points
From the paper's conclusion- Conclusion: The integration of PET/CT report semantics into automated PSMA PET/CT segmentation substantially reduced false-positive lesions and preserved total lesion PSMA agreement with manual measurements; a matched true-positive-only reanalysis indicated that the accompanying whole-mask boundary-agreement gains reflected false-positive suppression rather than improved contour accuracy on correc
Abstract
Whole-body prostate-specific membrane antigen (PSMA) PET/CT segmentation remains challenging: manual contouring is unsustainable, and image-only artificial intelligence models often misclassify physiologic uptake as malignant, causing high false-positive rates. These limitations underscore the need for segmentation strategies that incorporate the nuclear medicine expertise encoded in PET/CT reports but not used by current models. We investigated whether routine PET/CT reports improve automated lesion segmentation for prostate cancer. Methods: We developed a language-guided 3-dimensional SegResNet fusing report text with 68Ga-PSMA-11 PET/CT image features, encoding report semantics via 4 strategies (BiomedVLP, RadGraph, GPT-raw, GPT-engineered) compared with an image-only model (baseline). Of 320 patients who underwent 68Ga-PSMA-11 PET/CT, 297 studies were available; 13 were excluded for missing reports or incomplete image-mask pairs, leaving 284 for analysis, split at the patient level into 243 development cases and a fixed 41-case held-out test set. Metrics included Dice, intersection over union (IoU), precision, recall, average symmetric surface distance, 95th percentile Hausdorff distance, surface Dice similarity at 5 mm, and lesion-level false positives, using 3 matching criteria (any overlap; 1-to-1 maximum IoU matching, IoU ≥ 0.5; and correct localization of the SUVmax voxel). Significance was assessed using paired 1-sided Wilcoxon tests with Holm adjustment. Results: Report guidance consistently reduced false positives and improved whole-mask boundary agreement. False-positive lesions were reduced by nearly 4 per patient with BiomedVLP and by approximately 3 per patient with RadGraph and GPT-raw. Average symmetric surface distance decreased from 105.4 ± 62.5 mm (image only) to 23.4 ± 18.2 mm with BiomedVLP, 36.9 ± 22.4 mm with RadGraph, and 36.3 ± 26.4 mm with GPT-raw; 95th percentile Hausdorff distance improved from 455.0 ± 169.3 mm to 123.8 ± 80.3 mm with BiomedVLP, and surface Dice similarity at 5 mm increased from 0.638 ± 0.172 to 0.705 ± 0.181. However, when these surface metrics were recomputed on matched true-positive lesions only using the same 3 criteria, no language-guided model differed significantly from the image-only model for any surface metric (all Holm-adjusted P = 1.0), indicating that the whole-mask improvements were attributable to false-positive suppression rather than genuine gains in contour accuracy on correctly detected lesions. Precision increased for BiomedVLP (0.099) and RadGraph (0.060), with a modest decrease in voxel-level recall (-0.051, BiomedVLP), reflecting a precision-recall trade-off from suppression of spurious uptake. Dice improved by 0.032 but was borderline significant; IoU increased for BiomedVLP (0.036). Lesion-level sensitivity changed by no more than 0.04 for all models and did not reach significance. Total lesion PSMA remained highly correlated with manual measurements (r ≥ 0.85), whereas PSMA tumor volume correlations were more variable across models (r = 0.37-0.70). Conclusion: The integration of PET/CT report semantics into automated PSMA PET/CT segmentation substantially reduced false-positive lesions and preserved total lesion PSMA agreement with manual measurements; a matched true-positive-only reanalysis indicated that the accompanying whole-mask boundary-agreement gains reflected false-positive suppression rather than improved contour accuracy on correctly detected lesions. This approach may reduce manual cleanup and support more reliable quantitative workflows, although precision gains should be weighed against a modest recall reduction. External validation, extension of the true-positive-only analysis to independent cohorts, and PSMA-specific language pretraining are warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fully Automated Segmentation of [18F]FDG and [68Ga]/[18F]PSMA PET/CT Images via Data-Centric Deep Learning.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
- Can chatGPT-4o reliably standardize PSMA PET/CT and PET/MRI reports using PROMISE V2 criteria? - An exploratory studyEJNMMI Research · 2026
- LLM-powered prostate cancer staging from PSMA-PET/CT reports using PROMISE v2European Journal of Nuclear Medicine and Molecular Imaging · 2026
- Multi-task Deep Learning via UNETR for PSMA PET/CT Image for Prostate Cancer: Simultaneous Assessment of Prostate Cancer Disease Burden, Treatment Selection and Survival Outcomes.Journal of imaging informatics in medicine · 2026
- Automated PROMISE V2 Scoring from PSMA PET/CT Reports Using Large Language Models: A Comparative Evaluation of Prompt Design and Model PerformanceCurrent Oncology · 2026
- Augmenting Deep Learning-Based PSMA PET/CT Metastasis Segmentation With a Population-Level Spatial Atlas.medRxiv : the preprint server for health sciences · 2026