Robot-Assisted Navigation for Infinity Total Ankle Arthroplasty: Technique Tip.
Jingqi Liang, Hongmou Zhao
Department of Foot and Ankle Surgery, Xi'an Honghui Hospital, Xi'an Jiaotong University, China.
Key points
From the paper's conclusion- Robotic navigation-assisted total ankle arthroplasty provides precise pin placement, reduces radiation, shortens tourniquet time, and may lower wound complications. It may shorten the learning curve for less experienced surgeons and merits broader use. Long-term survivorship data are still needed.
Abstract
OBJECTIVES: Long-term survivorship of total ankle arthroplasty depends on coronal alignment. Short-term complications include wound infection. Conventional extramedullary guides need repeated fluoroscopy, prolonging operative and tourniquet time, increasing contamination, and wound complications. Patient-specific instrumentation has long cycles and high costs. MATERIAL AND METHODS: This study presents a robotic-assisted technique for Infinity total ankle arthroplasty using the TiRobot system. After O-arm 3D scanning, the guide pin trajectory was planned perpendicular to the tibial mechanical axis in coronal and sagittal planes, and centered in the ankle mortise axially. The robotic arm rigidly placed the pins, followed by standard osteotomy and implantation. A comparative review included 42 robotic-assisted and 71 conventional cases. RESULTS: In the robotic group, the mean operative time was 75.4±10.2 min, tourniquet time was 60.5±8.5 min. Mean fluoroscopic shots were 28.2±3.4, with a mean time of 32 seconds-about 50% less radiation than conventional methods. Minor delayed wound healing occurred in 2 cases (5%), lower than reported rates. The O-arm scan added a single radiation bolus to the patient but eliminated the surgeon's fluoroscopy exposure. CONCLUSION: Robotic navigation-assisted total ankle arthroplasty provides precise pin placement, reduces radiation, shortens tourniquet time, and may lower wound complications. It may shorten the learning curve for less experienced surgeons and merits broader use. Long-term survivorship data are still needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy and Precision of Computer-assisted Navigation Compared With Patient-Specific Instrumentation and Conventional Methods in Total Ankle Arthroplasty.The Journal of the American Academy of Orthopaedic Surgeons · 2026
- Robotic navigation-assisted versus conventional freehand placement of the infra-acetabular screw in acetabular fracture surgery: A retrospective comparative study.Injury · 2026
- Imageless robotic assistance versus laser-projected mechanical-axis guidance in total knee arthroplasty: a deformity-stratified comparative cohort study.Journal of robotic surgery · 2026
- TiRobot-assisted cannulated screw fixation for calcaneal fractures: a meta-analysis of surgical trauma, anatomical restoration, and functional recovery.Frontiers in surgery · 2026
- Clinical application of robot-assisted fixation for calcaneal fractures: a meta-analysis with subgroup comparisons.Journal of robotic surgery · 2026
- Pre-clinical evaluation of a smartphone-assisted navigation system for surgical pin positioning in total knee arthroplasty.Medical engineering & physics · 2026