Timed saliva sampling as a new reliable marker for assessing iodine intake.
Adrijana Oblak, Jernej Imperl, Mitja Kolar, Gregor Marolt, Blaz Krhin, Katja Zaletel, Simona Gaberscek
1Division of Nuclear Medicine, University Medical Centre Ljubljana, Ljubljana, Slovenia. · 3Faculty of Chemistry and Chemical Technology, University of Ljubljana, Ljubljana, Slovenia.
Key points
From the paper's conclusion- We found an excellent correlation between SLIC values and UIE, where the SLIC value depends on the sampling timing and/or number of meals. SLIC measurement could replace UIE measurement and represents an important and possible new biomarker for assessing iodine intake.
Abstract
BACKGROUND: Iodine is an essential component of thyroid hormones. Therefore, sufficient iodine intake is important for adequate thyroid function. Measuring the urinary iodine concentration (UIC) is the recommended method for assessing population iodine intake, but it has certain drawbacks. In addition to urine, iodine is also excreted into saliva. Therefore, the aim of our work was to determine whether salivary iodine concentration (SLIC) measurement could replace UIC measurements, even a gold standard, urinary iodine excretion (UIE) in the 24-hour urine. We also evaluated the influence of saliva collection time on SLIC measurements. SUBJECTS AND METHODS: We invited adult volunteers who first provided 24-hour urine and saliva samples collected on the same day at home, strictly according to the protocol. UIC and SLIC before and after meals were measured using the Sandell-Kolthoff method, comparable to inductively coupled plasma mass spectrometry. RESULTS: The study included 104 healthy participants from whom all biological samples were completely collected. Importantly, none of them was taking thyroid medication or iodine supplements and all were without thyroid disease. A very good correlation of SLIC values at 60 and 120 min after the first and second meal and 30 min after the second, third, and fourth meals with UIE was observed (P>0.05). CONCLUSIONS: We found an excellent correlation between SLIC values and UIE, where the SLIC value depends on the sampling timing and/or number of meals. SLIC measurement could replace UIE measurement and represents an important and possible new biomarker for assessing iodine intake.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of deficient and excessive iodine intake on salivary iodine transport and NIS/TSHR expression in rats.Open life sciences · 2026
- Ten consecutive days of spot urine sampling provide stable estimations of individual urinary iodine excretion.The Journal of nutrition · 2026
- Urinary iodine concentrations in the general population – a cross-sectional analysis of dietary and cardio-metabolic correlatesFrontiers in Nutrition · 2026
- Scalp hair and serum iodine as potential biomarkers for iodine intake and their association with the thyroid functionJournal of the Endocrine Society · 2026
- A-209 A Basic Study of Stress Measurement Methods Using Salivary Amylase ActivityClinical Chemistry · 2026
- Detection of serum amyloid A in Saliva of patients with internal carotid artery stenosis: a pilot study.Clinical oral investigations · 2026