Clinical Chemistry

A-209 A Basic Study of Stress Measurement Methods Using Salivary Amylase Activity

Hina Ito, Rino Higa, Momoka Saito, Ryo Kubota

Key points

From the paper's conclusion
  • In conclusion, although absolute values differed, both methods successfully detected decreased amylase activity after stress relief.

Abstract

Background According to recent government surveys, the percentage of people citing stress as a major health risk has tripled over the past 20 years. Traditional psychological questionnaires for stress assessment are subjective and may allow intentional manipulation of scores, highlighting the need for objective physiological evaluation methods. Measuring salivary alpha-amylase activity is a simple and objective method for this purpose, as stress stimulates the sympathetic nervous system, triggering amylase secretion via noradrenaline. This study aimed to analyze amylase activity before and after a stress-relief intervention using a salivary amylase monitor [A6.1]and the ethylidene-4-nitrophenyl-a-D-maltoheptaoside (Et-G7-PNP[A7.1]) substrate reagent. Methods The subjects were four female university students[A8.1]. A mock national examination was conducted to induce stress. Saliva samples were collected twice: Once under stress (before relief) and once after a stress-relief intervention using lavender aromatherapy. Two measurement systems were used: A salivary amylase monitor and the Alpha-Amylase Measurement Kit G7. Additionally, two saliva collection methods were compared: Sublingual and spot (direct dripping) methods. Results (1) Collection Methods: The salivary amylase monitor revealed a significant difference in activity values between the sublingual and spot collection methods. (2) Changes after Stress Relief: Both the salivary amylase monitor (spot method) and Et-G7-PNP reagent revealed decreased salivary alpha-amylase activity after the stress-relief intervention. (3) Substrate Comparison: A marked difference was noted between the absolute values measured by the monitor and those measured by the reagent. Conclusion The discrepancy between the two collection methods was possibly due to differences in saliva viscosity and volume, which affected absorption into the test paper. Regarding the divergence between the two measurement systems, the monitor used 2-chloro-4-nitrophenol-4-O-ß-D-galactopyranosylmaltoside[A9.1], whereas the reagent used Et-G7-PNP as a substrate. Literature suggests that discrepancies between these substrates increase at low pancreatic amylase activity; a similar mechanism may underlie salivary amylase activity. In conclusion, although absolute values differed, both methods successfully detected decreased amylase activity after stress relief. Overall, our results suggest that alpha-amylase activity measured via the spot collection method using a monitor is a valid indicator of stress relief.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A-209 A Basic Study of Stress Measurement Methods Using Salivary Amylase Activity — Science Skim