The Relationship Between Indoor Classroom Noise Levels and the Operating State of the Ventilation System
Antonia Iordache, Catalin Lungu, Vlad Iordache
Key points
From the paper's conclusion- Furthermore, an exponential correlation was established between the indoor noise level variation and the operating state of the ventilation equipment.
Abstract
The evolution of the outdoor climate, combined with the quality requirements imposed on educational environments, leads to special scenarios that are not currently covered by existing noise protection standards. In this study, we present an acoustic analysis of such a scenario, where a noise-generating ventilation unit is installed inside a classroom. In-situ measurements of both sound pressure levels and overall A-weighted sound pressure levels were conducted within the classroom across various operating states of the ventilation equipment. Regardless of the operating mode, the measured noise level remained below the acoustic comfort limit. A low variation in noise levels was observed throughout the interior of the classroom. Slightly higher values were recorded near the noise source, whereas lower values were observed in the corner opposite the equipment. Furthermore, an exponential correlation was established between the indoor noise level variation and the operating state of the ventilation equipment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Spatial Assessment of Environmental Noise Across Hospital Functional Zones: A Cross-Sectional Observational Study in a Tertiary Hospital.Journal of visualized experiments : JoVE · 2026
- Voice Changes Related to Perceived Indoor Air Quality in Finnish Teachers: A Proof-of-Concept Field Study.International journal of environmental research and public health · 2026
- Baseline Constraints in Classroom Acoustic Screening: An Inverse Analysis with a Fixed Baseline and Attenuated Open-State IncrementBuildings · 2026
- Classroom indoor air quality and its association with sick Building syndrome (SBS) symptoms in a Malaysian university settingScientific Reports · 2025
- Measurement-driven GIS mapping of short-term outdoor campus noise at Batman University, Türkiye: A WHO-informed screening approach.Environmental monitoring and assessment · 2026
- Indoor Air Quality and Occupant Perception in an Office Building Adapted for Educational Use: A Zone‐Based Case StudyIndoor Air · 2026